Reference record for OID 1.3.6.1.4.1.259.10.1.24.1.2.1.1.12

Parent
1.3.6.1.4.1.259.10.1.24.1.2.1.1 (portEntry)
Node code
12
Node name
portComboForcedMode
Numeric OID
1.3.6.1.4.1.259.10.1.24.1.2.1.1.12
URN notation
urn:oid:1.3.6.1.4.1.259.10.1.24.1.2.1.1.12
ASN.1 notation

{1 3 6 1 4 1 259 10 1 24 1 2 1 1 12}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgecoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgeCoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) cheetahSwitchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) switchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) edgecoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) edgeCoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) cheetahSwitchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) switchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) edgecoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) edgeCoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) cheetahSwitchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) switchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) edgecoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) edgeCoreNetworksMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) cheetahSwitchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) switchMgt(1) ecs4510MIB(24) ecs4510MIBObjects(1) portMgt(2) portTable(1) portEntry(1) portComboForcedMode(12)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/259/10/1/24/1/2/1/1/12
  • /ISO/Identified-Organization/6/1/4/1/259/10/1/24/1/2/1/1/12
  • /ISO/3/6/1/4/1/259/10/1/24/1/2/1/1/12
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgecoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgeCoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/cheetahSwitchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/switchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/edgecoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/edgeCoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/cheetahSwitchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/switchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/edgecoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/edgeCoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/cheetahSwitchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/switchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/edgecoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/edgeCoreNetworksMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/cheetahSwitchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/switchMgt/ecs4510MIB/ecs4510MIBObjects/portMgt/portTable/portEntry/portComboForcedMode
  • Additional combinations skipped.

Descriptions

portComboForcedMode — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

This determines the running mode of a combo port. For a non-combo port, this variable has a value of none(1), and setting this variable to none(1) has no effect. For a combo port, this has its own valid values not equal to none(1), and setting this variable to none(1) is not allowed. copperForced(2) is set if user wants to force this combo port to run in copper mode. copperPreferredAuto(3) is obsoleted, and user shall not set this state. sfpForced(4) is set if user wants to force this combo port to run in fiber mode. sfpPreferredAuto(5) is set if user wants to change copper or fiber mode automatically by SFP transceiver present state. If SFP transceiver is present, this combo port will run in fiber mode, and if SFP transceiver is not present, this combo port will run in copper mode.

portComboForcedMode — Edgecore MIB copies (Observium Community)

This determines the running mode of a fiber port. For a non-combo port, this variable has a value of none(1), and setting this variable to none(1) has no effect. For a combo port, this has its own valid values not equal to none(1), and setting this variable to none(1) is not allowed. copperForced(2) is set if user wants to force this combo port to run in copper mode. copperPreferredAuto(3) is obsoleted, and user shall not set this state. sfpPreferredAuto(5) is set if user wants to change copper or fiber mode automatically by SFP transceiver present state. If SFP transceiver is present, this combo port will run in fiber mode, and if SFP transceiver is not present, this combo port will run in copper mode. sfpForced100Fx(6) is set if user wants to force this fiber port to run in fiber mode with speed 100Mbps. sfpForced1000Sfp(7) is set if user wants to force this fiber port to run in fiber mode with speed 1Gbps. sfpForced10gSfp(8) is set if user wants to force this fiber port to run in fiber mode with speed 10Gbps.

Source records

portComboForcedMode

Status in source: current.

Names: portComboForcedMode

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "portComboForcedMode",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "none",
    "(",
    "1",
    ")",
    ",",
    "copperForced",
    "(",
    "2",
    ")",
    ",",
    "copperPreferredAuto",
    "(",
    "3",
    ")",
    ",",
    "sfpForced",
    "(",
    "4",
    ")",
    ",",
    "sfpPreferredAuto",
    "(",
    "5",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This determines the running mode of a combo port. For a non-combo port, this variable has a value of none(1), and setting this variable to none(1) has no effect. For a combo port, this has its own valid values not equal to none(1), and setting this variable to none(1) is not allowed. copperForced(2) is set if user wants to force this combo port to run in copper mode. copperPreferredAuto(3) is obsoleted, and user shall not set this state. sfpForced(4) is set if user wants to force this combo port to run in fiber mode. sfpPreferredAuto(5) is set if user wants to change copper or fiber mode automatically by SFP transceiver present state. If SFP transceiver is present, this combo port will run in fiber mode, and if SFP transceiver is not present, this combo port will run in copper mode.\"",
    "::=",
    "{",
    "portEntry",
    "12",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "none",
            1
          ],
          [
            "copperForced",
            2
          ],
          [
            "copperPreferredAuto",
            3
          ],
          [
            "sfpForced",
            4
          ],
          [
            "sfpPreferredAuto",
            5
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This determines the running mode of a combo port. For a non-combo port, this variable has a value of none(1), and setting this variable to none(1) has no effect. For a combo port, this has its own valid values not equal to none(1), and setting this variable to none(1) is not allowed. copperForced(2) is set if user wants to force this combo port to run in copper mode. copperPreferredAuto(3) is obsoleted, and user shall not set this state. sfpForced(4) is set if user wants to force this combo port to run in fiber mode. sfpPreferredAuto(5) is set if user wants to change copper or fiber mode automatically by SFP transceiver present state. If SFP transceiver is present, this combo port will run in fiber mode, and if SFP transceiver is not present, this combo port will run in copper mode."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: ECS4510-MIB

    Vendor MIB copy from the LibreNMS archive.

    Module: ECS4510-MIB

    Published definition
    portComboForcedMode  OBJECT-TYPE
           SYNTAX     INTEGER
                      {
                        none(1),
                        copperForced(2),
                        copperPreferredAuto(3),
                        sfpForced(4),
                        sfpPreferredAuto(5)
                      }
           MAX-ACCESS read-write
           STATUS     current
           DESCRIPTION "This determines the running mode of a combo port.
                        For a non-combo port, this variable has a value of none(1),
                        and setting this variable to none(1) has no effect.
                        For a combo port, this has its own valid values not
                        equal to none(1), and setting this variable to none(1) is
                        not allowed. copperForced(2) is set if user wants to force
                        this combo port to run in copper mode. copperPreferredAuto(3)
                        is obsoleted, and user shall not set this state. sfpForced(4)
                        is set if user wants to force this combo port to run in fiber
                        mode. sfpPreferredAuto(5) is set if user wants to change copper or
                        fiber mode automatically by SFP transceiver present state. If SFP
                        transceiver is present, this combo port will run in fiber mode, and
                        if SFP transceiver is not present, this combo port will run in
                        copper mode."
           ::= { portEntry 12}
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}
    · Download ECS4510-MIB

    Related source files and packages:


    Source location: ECS4510-MIB::portComboForcedMode.
    Source version and references

    Downloaded: 2026-10-24T02:14:14.750310+00:00.

portComboForcedMode

Status in source: current.

Names: portComboForcedMode

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "portComboForcedMode",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "none",
    "(",
    "1",
    ")",
    ",",
    "copperForced",
    "(",
    "2",
    ")",
    ",",
    "copperPreferredAuto",
    "(",
    "3",
    ")",
    ",",
    "reserved4",
    "(",
    "4",
    ")",
    ",",
    "sfpPreferredAuto",
    "(",
    "5",
    ")",
    ",",
    "sfpForced100Fx",
    "(",
    "6",
    ")",
    ",",
    "sfpForced1000Sfp",
    "(",
    "7",
    ")",
    ",",
    "sfpForced10gSfp",
    "(",
    "8",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This determines the running mode of a fiber port. For a non-combo port, this variable has a value of none(1), and setting this variable to none(1) has no effect. For a combo port, this has its own valid values not equal to none(1), and setting this variable to none(1) is not allowed. copperForced(2) is set if user wants to force this combo port to run in copper mode. copperPreferredAuto(3) is obsoleted, and user shall not set this state. sfpPreferredAuto(5) is set if user wants to change copper or fiber mode automatically by SFP transceiver present state. If SFP transceiver is present, this combo port will run in fiber mode, and if SFP transceiver is not present, this combo port will run in copper mode. sfpForced100Fx(6) is set if user wants to force this fiber port to run in fiber mode with speed 100Mbps. sfpForced1000Sfp(7) is set if user wants to force this fiber port to run in fiber mode with speed 1Gbps. sfpForced10gSfp(8) is set if user wants to force this fiber port to run in fiber mode with speed 10Gbps.\"",
    "::=",
    "{",
    "portEntry",
    "12",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "none",
            1
          ],
          [
            "copperForced",
            2
          ],
          [
            "copperPreferredAuto",
            3
          ],
          [
            "reserved4",
            4
          ],
          [
            "sfpPreferredAuto",
            5
          ],
          [
            "sfpForced100Fx",
            6
          ],
          [
            "sfpForced1000Sfp",
            7
          ],
          [
            "sfpForced10gSfp",
            8
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This determines the running mode of a fiber port. For a non-combo port, this variable has a value of none(1), and setting this variable to none(1) has no effect. For a combo port, this has its own valid values not equal to none(1), and setting this variable to none(1) is not allowed. copperForced(2) is set if user wants to force this combo port to run in copper mode. copperPreferredAuto(3) is obsoleted, and user shall not set this state. sfpPreferredAuto(5) is set if user wants to change copper or fiber mode automatically by SFP transceiver present state. If SFP transceiver is present, this combo port will run in fiber mode, and if SFP transceiver is not present, this combo port will run in copper mode. sfpForced100Fx(6) is set if user wants to force this fiber port to run in fiber mode with speed 100Mbps. sfpForced1000Sfp(7) is set if user wants to force this fiber port to run in fiber mode with speed 1Gbps. sfpForced10gSfp(8) is set if user wants to force this fiber port to run in fiber mode with speed 10Gbps."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Edgecore MIB copies (Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. Edgecore support.

    Module: ECS4510-MIB

    Published definition
    portComboForcedMode  OBJECT-TYPE
           SYNTAX     INTEGER
                      {
                        none(1),
                        copperForced(2),
                        copperPreferredAuto(3),
                        reserved4(4),
                        sfpPreferredAuto(5),
                        sfpForced100Fx(6),
                        sfpForced1000Sfp(7),
                        sfpForced10gSfp(8)
                      }
           MAX-ACCESS read-write
           STATUS     current
           DESCRIPTION "This determines the running mode of a fiber port.
                        For a non-combo port, this variable has a value of none(1),
                        and setting this variable to none(1) has no effect.
                        For a combo port, this has its own valid values not
                        equal to none(1), and setting this variable to none(1) is
                        not allowed. copperForced(2) is set if user wants to force
                        this combo port to run in copper mode. copperPreferredAuto(3)
                        is obsoleted, and user shall not set this state. sfpPreferredAuto(5)
                        is set if user wants to change copper or fiber mode automatically
                        by SFP transceiver present state. If SFP transceiver is present,
                        this combo port will run in fiber mode, and if SFP transceiver is
                        not present, this combo port will run in copper mode. sfpForced100Fx(6)
                        is set if user wants to force this fiber port to run in fiber mode with
                        speed 100Mbps. sfpForced1000Sfp(7) is set if user wants to force this
                        fiber port to run in fiber mode with speed 1Gbps. sfpForced10gSfp(8) is
                        set if user wants to force this fiber port to run in fiber mode with
                        speed 10Gbps."
           ::= { portEntry 12}
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}
    · Download ECS4510-MIB

    Related source files and packages:


    Source location: ECS4510-MIB::portComboForcedMode.
    Source version and references

    Downloaded: 2026-10-23T19:26:18.217244+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.259)

Rooney Don

Siblings (13)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.259.10.1.24.1.2.1.1.1 portIndex00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.2 portName00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.3 portType00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.4 portSpeedDpxCfg00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.5 portFlowCtrlCfg00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.6 portCapabilities00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.7 portAutonegotiation00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.8 portSpeedDpxStatus00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.9 portFlowCtrlStatus00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.10 portTrunkIndex00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.15 portMasterSlaveModeCfg00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.17 portMacAddrLearningStatus00
1.3.6.1.4.1.259.10.1.24.1.2.1.1.18 portMacAddrLearningCount00