Reference record for OID 1.3.6.1.4.1.259.10.1.55.1.5.2.1.20

Parent
1.3.6.1.4.1.259.10.1.55.1.5.2.1 (staPortEntry)
Node code
20
Node name
staPortBpduGuardAutoRecoveryInterval
Numeric OID
1.3.6.1.4.1.259.10.1.55.1.5.2.1.20
URN notation
urn:oid:1.3.6.1.4.1.259.10.1.55.1.5.2.1.20
ASN.1 notation

{1 3 6 1 4 1 259 10 1 55 1 5 2 1 20}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgecoreNetworksMgt(1) ecs4150MIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgecoreNetworksMgt(1) ecs4150MIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgecoreNetworksMgt(1) ecs4150tipMIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgecoreNetworksMgt(1) ecs4150tipMIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgeCoreNetworksMgt(1) ecs4150MIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgeCoreNetworksMgt(1) ecs4150MIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgeCoreNetworksMgt(1) ecs4150tipMIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgeCoreNetworksMgt(1) ecs4150tipMIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) cheetahSwitchMgt(1) ecs4150MIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) cheetahSwitchMgt(1) ecs4150MIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) cheetahSwitchMgt(1) ecs4150tipMIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) cheetahSwitchMgt(1) ecs4150tipMIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) switchMgt(1) ecs4150MIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) switchMgt(1) ecs4150MIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) switchMgt(1) ecs4150tipMIB(55) ecs4150MIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) switchMgt(1) ecs4150tipMIB(55) ecs4150tipMIBObjects(1) staMgt(5) staPortTable(2) staPortEntry(1) staPortBpduGuardAutoRecoveryInterval(20)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/259/10/1/55/1/5/2/1/20
  • /ISO/Identified-Organization/6/1/4/1/259/10/1/55/1/5/2/1/20
  • /ISO/3/6/1/4/1/259/10/1/55/1/5/2/1/20
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgecoreNetworksMgt/ecs4150MIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgecoreNetworksMgt/ecs4150MIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgecoreNetworksMgt/ecs4150tipMIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgecoreNetworksMgt/ecs4150tipMIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgeCoreNetworksMgt/ecs4150MIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgeCoreNetworksMgt/ecs4150MIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgeCoreNetworksMgt/ecs4150tipMIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgeCoreNetworksMgt/ecs4150tipMIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/cheetahSwitchMgt/ecs4150MIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/cheetahSwitchMgt/ecs4150MIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/cheetahSwitchMgt/ecs4150tipMIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/cheetahSwitchMgt/ecs4150tipMIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/switchMgt/ecs4150MIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/switchMgt/ecs4150MIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/switchMgt/ecs4150tipMIB/ecs4150MIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/switchMgt/ecs4150tipMIB/ecs4150tipMIBObjects/staMgt/staPortTable/staPortEntry/staPortBpduGuardAutoRecoveryInterval
  • Additional combinations skipped.

Descriptions

staPortBpduGuardAutoRecoveryInterval — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Edgecore official enterprise switch MIBs

The interval in seconds used by BPDU guard auto recovery mechanism.

Source records

staPortBpduGuardAutoRecoveryInterval

Status in source: current.

Names: staPortBpduGuardAutoRecoveryInterval

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "staPortBpduGuardAutoRecoveryInterval",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "(",
    "30",
    ".",
    ".",
    "86400",
    ")",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The interval in seconds used by BPDU guard auto recovery mechanism.\"",
    "::=",
    "{",
    "staPortEntry",
    "20",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32",
      [
        "integerSubType",
        [
          [
            30,
            86400
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The interval in seconds used by BPDU guard auto recovery mechanism."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS4150_20250806p.mib

    Module: ECS4150-MIB

    Published definition
    staPortBpduGuardAutoRecoveryInterval    OBJECT-TYPE
        SYNTAX      Unsigned32(30..86400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "The interval in seconds used by BPDU guard auto recovery
                     mechanism."
        ::= { staPortEntry 20 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS4150-MIB::staPortBpduGuardAutoRecoveryInterval.
    Source version and references

    Same file in 55684972545049.

    Downloaded: 2026-10-23T18:27:38.309065+00:00.

  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS4150_202603310000Z.mib

    Module: ECS4150-MIB

    Published definition
    staPortBpduGuardAutoRecoveryInterval    OBJECT-TYPE
        SYNTAX      Unsigned32(30..86400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "The interval in seconds used by BPDU guard auto recovery
                     mechanism."
        ::= { staPortEntry 20 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS4150-MIB::staPortBpduGuardAutoRecoveryInterval.
    Source version and references

    Downloaded: 2026-10-23T18:27:37.449889+00:00.

  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS4150_202605180000Z.mib

    Module: ECS4150-MIB

    Published definition
    staPortBpduGuardAutoRecoveryInterval    OBJECT-TYPE
        SYNTAX      Unsigned32(30..86400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "The interval in seconds used by BPDU guard auto recovery
                     mechanism."
        ::= { staPortEntry 20 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS4150-MIB::staPortBpduGuardAutoRecoveryInterval.
    Source version and references

    Same file in 62786165040153.

    Downloaded: 2026-10-23T18:27:39.349916+00:00.

  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS4150_202606120000Z.mib

    Module: ECS4150-MIB

    Published definition
    staPortBpduGuardAutoRecoveryInterval    OBJECT-TYPE
        SYNTAX      Unsigned32(30..86400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "The interval in seconds used by BPDU guard auto recovery
                     mechanism."
        ::= { staPortEntry 20 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS4150-MIB::staPortBpduGuardAutoRecoveryInterval.
    Source version and references

    Downloaded: 2026-10-23T18:27:44.768000+00:00.

  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS4150_202605120000Z.mib

    Module: ECS4150TIP-MIB

    Published definition
    staPortBpduGuardAutoRecoveryInterval    OBJECT-TYPE
        SYNTAX      Unsigned32(30..86400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "The interval in seconds used by BPDU guard auto recovery
                     mechanism."
        ::= { staPortEntry 20 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS4150TIP-MIB::staPortBpduGuardAutoRecoveryInterval.
    Source version and references

    Downloaded: 2026-10-23T18:27:42.970294+00:00.

  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS4150_202609220000Z.mib

    Module: ECS4150TIP-MIB

    Published definition
    staPortBpduGuardAutoRecoveryInterval    OBJECT-TYPE
        SYNTAX      Unsigned32(30..86400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "The interval in seconds used by BPDU guard auto recovery
                     mechanism."
        ::= { staPortEntry 20 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS4150TIP-MIB::staPortBpduGuardAutoRecoveryInterval.
    Source version and references

    Downloaded: 2026-10-23T18:27:45.671041+00:00.

  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: ECS4150-MIB

    Vendor MIB copy from the LibreNMS archive.

    Module: ECS4150-MIB

    Published definition
    staPortBpduGuardAutoRecoveryInterval    OBJECT-TYPE
        SYNTAX      Unsigned32(30..86400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION "The interval in seconds used by BPDU guard auto recovery
                     mechanism."
        ::= { staPortEntry 20 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Related source files and packages:


    Source location: ECS4150-MIB::staPortBpduGuardAutoRecoveryInterval.
    Source version and references

    Downloaded: 2026-10-24T02:14:14.738310+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.259)

Rooney Don

Siblings (14)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.259.10.1.55.1.5.2.1.3 staPortProtocolMigration00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.5 staPortOperEdgePort00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.6 staPortAdminPointToPoint00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.7 staPortOperPointToPoint00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.9 staPortSystemStatus00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.10 staPortLongAdminPathCost00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.11 staPortLongOperPathCost00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.12 staPortBpduFlooding00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.15 staPortBpduGuard00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.16 staPortAdminEdgePortWithAuto00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.17 staPortBpduFilter00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.18 staPortRootGuardStatus00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.19 staPortBpduGuardAutoRecovery00
1.3.6.1.4.1.259.10.1.55.1.5.2.1.21 staPortTcPropStop00