swPowerStatus — Edgecore official enterprise switch MIBs
Indicates the switch using internalPower(1), redundantPower(2) or both(3)
{1 3 6 1 4 1 259 10 1 62 1 1 3 1 8}
Indicates the switch using internalPower(1), redundantPower(2) or both(3)
Status in source: current.
Names: swPowerStatus
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"swPowerStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"internalPower",
"(",
"1",
")",
",",
"redundantPower",
"(",
"2",
")",
",",
"internalAndRedundantPower",
"(",
"3",
")",
",",
"externalPower",
"(",
"4",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the switch using internalPower(1), redundantPower(2) or both(3)\"",
"::=",
"{",
"switchInfoEntry",
"8",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"internalPower",
1
],
[
"redundantPower",
2
],
[
"internalAndRedundantPower",
3
],
[
"externalPower",
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the switch using internalPower(1), redundantPower(2) or both(3)"
],
null,
null,
null,
null
]
}Module: ECS5550-MIB
swPowerStatus OBJECT-TYPE
SYNTAX INTEGER
{
internalPower(1),
redundantPower(2),
internalAndRedundantPower(3),
externalPower(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the switch using internalPower(1),
redundantPower(2) or both(3)"
::= { switchInfoEntry 8 }{'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}Same file in 59284526091801.
Same file in 56335088769433.
Downloaded: 2026-10-23T18:27:34.967489+00:00.
Module: ECS5550-MIB
swPowerStatus OBJECT-TYPE
SYNTAX INTEGER
{
internalPower(1),
redundantPower(2),
internalAndRedundantPower(3),
externalPower(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the switch using internalPower(1),
redundantPower(2) or both(3)"
::= { switchInfoEntry 8 }{'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}Downloaded: 2026-10-23T18:27:44.207709+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.1 | swUnitIndex | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.2 | swHardwareVer | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.3 | swMicrocodeVer | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.4 | swLoaderVer | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.5 | swBootRomVer | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.6 | swOpCodeVer | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.7 | swPortNumber | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.9 | swRoleInSystem | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.10 | swSerialNumber | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.13 | swServiceTag | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.14 | swModelNumber | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.62.1.1.3.1.15 | swEpldVer | 0 | 0 |