Reference record for OID 1.3.6.1.4.1.259.10.1.62.1.1.3.1.8

Parent
1.3.6.1.4.1.259.10.1.62.1.1.3.1 (switchInfoEntry)
Node code
8
Node name
swPowerStatus
Numeric OID
1.3.6.1.4.1.259.10.1.62.1.1.3.1.8
URN notation
urn:oid:1.3.6.1.4.1.259.10.1.62.1.1.3.1.8
ASN.1 notation

{1 3 6 1 4 1 259 10 1 62 1 1 3 1 8}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgecoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) edgeCoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) cheetahSwitchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecoreNetworks(10) switchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) edgecoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) edgeCoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) cheetahSwitchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecorenetworks(10) switchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) edgecoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) edgeCoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) cheetahSwitchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) edgecore(10) switchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) edgecoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) edgeCoreNetworksMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) cheetahSwitchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) accton(259) snmpMgt(10) switchMgt(1) ecs5550MIB(62) ecs5550MIBObjects(1) switchMgt(1) switchInfoTable(3) switchInfoEntry(1) swPowerStatus(8)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/259/10/1/62/1/1/3/1/8
  • /ISO/Identified-Organization/6/1/4/1/259/10/1/62/1/1/3/1/8
  • /ISO/3/6/1/4/1/259/10/1/62/1/1/3/1/8
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgecoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/edgeCoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/cheetahSwitchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecoreNetworks/switchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/edgecoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/edgeCoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/cheetahSwitchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecorenetworks/switchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/edgecoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/edgeCoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/cheetahSwitchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/edgecore/switchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/edgecoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/edgeCoreNetworksMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/cheetahSwitchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/259/snmpMgt/switchMgt/ecs5550MIB/ecs5550MIBObjects/switchMgt/switchInfoTable/switchInfoEntry/swPowerStatus
  • Additional combinations skipped.

Descriptions

swPowerStatus — Edgecore official enterprise switch MIBs

Indicates the switch using internalPower(1), redundantPower(2) or both(3)

Source records

swPowerStatus

Status in source: current.

Names: swPowerStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "swPowerStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "internalPower",
    "(",
    "1",
    ")",
    ",",
    "redundantPower",
    "(",
    "2",
    ")",
    ",",
    "internalAndRedundantPower",
    "(",
    "3",
    ")",
    ",",
    "externalPower",
    "(",
    "4",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Indicates the switch using internalPower(1), redundantPower(2) or both(3)\"",
    "::=",
    "{",
    "switchInfoEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "internalPower",
            1
          ],
          [
            "redundantPower",
            2
          ],
          [
            "internalAndRedundantPower",
            3
          ],
          [
            "externalPower",
            4
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Indicates the switch using internalPower(1), redundantPower(2) or both(3)"
    ],
    null,
    null,
    null,
    null
  ]
}
  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS5550_202507280000Z.mib

    Module: ECS5550-MIB

    Published definition
    swPowerStatus OBJECT-TYPE
            SYNTAX      INTEGER
                        {
                            internalPower(1),
                            redundantPower(2),
                            internalAndRedundantPower(3),
                            externalPower(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION "Indicates the switch using internalPower(1),
                         redundantPower(2) or both(3)"
            ::= { switchInfoEntry 8 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS5550-MIB::swPowerStatus.
    Source version and references

    Same file in 59284526091801.

    Same file in 56335088769433.

    Downloaded: 2026-10-23T18:27:34.967489+00:00.

  • Edgecore official enterprise switch MIBs · Publisher's source file: ECS5550_202609090000Z.mib

    Module: ECS5550-MIB

    Published definition
    swPowerStatus OBJECT-TYPE
            SYNTAX      INTEGER
                        {
                            internalPower(1),
                            redundantPower(2),
                            internalAndRedundantPower(3),
                            externalPower(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION "Indicates the switch using internalPower(1),
                         redundantPower(2) or both(3)"
            ::= { switchInfoEntry 8 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'OSPF-MIB': ['TOSType', 'Metric'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'MacAddress', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Counter64', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength'], 'POWER-ETHERNET-MIB': ['pethPsePortEntry', 'pethMainPseEntry']}

    Source location: ECS5550-MIB::swPowerStatus.
    Source version and references

    Downloaded: 2026-10-23T18:27:44.207709+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.259)

Rooney Don

Siblings (12)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.259.10.1.62.1.1.3.1.1 swUnitIndex00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.2 swHardwareVer00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.3 swMicrocodeVer00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.4 swLoaderVer00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.5 swBootRomVer00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.6 swOpCodeVer00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.7 swPortNumber00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.9 swRoleInSystem00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.10 swSerialNumber00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.13 swServiceTag00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.14 swModelNumber00
1.3.6.1.4.1.259.10.1.62.1.1.3.1.15 swEpldVer00