State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2634.1.280.14
State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)
Identification
{1 3 6 1 4 1 2634 1 280 14}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.2634.1.280.14.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
alarmLostOptoVoltage OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 14 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: alarmLostOptoVoltage
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"alarmLostOptoVoltage",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)\"",
"::=",
"{",
"alarmTables",
"14",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: WTI-CONSOLE-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'enterprises']}Related source files and packages:
Same file in Observium Community.
Vendor MIB copy from the Observium Community archive.
Module: WTI-RSM-TSM-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'enterprises']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2634.1.280.1 | alarmOverCurrentInitial | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.2 | alarmOverCurrentCritical | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.3 | alarmOverTemperatureInitial | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.4 | alarmOverTemperatureCritical | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.5 | alarmCircuitBreakerOpen | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.6 | alarmCommLoss | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.7 | alarmLostVoltage | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.8 | alarmPingNoAnswer | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.9 | alarmInvalidAccessLockout | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.10 | alarmPowerCycle | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.11 | alarmBufferThreshold | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.13 | alarmPlugCurrent | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.15 | alarmEmergencyShutoff | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.16 | alarmNoDialtone | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.17 | alarmWakeupOnFailure | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.18 | alarmIpPassthroughDataUsage | 0 | 0 | |
| 1.3.6.1.4.1.2634.1.280.19 | alarmBufferFiltering | 0 | 0 |