This object indicates the version of the PDUs used to perform Loss Measurement. The value is placed in the Version field of the PDU and indicates that the PDU format used is the format defined in Y.1731 with that version. The exact PDUs to use are specified by this object in combination with jnxSoamLmCfgType. This object can only be written at row creation time and cannot be modified once it has been created.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Juniper official MIBsNetdisco MIB archive copies