When written, binds the switch number entry to an attached switch; when read, 0 is returned.
Sources for this description
IBM MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.26543.2.7.7.12.1.1.2.1.4
When written, binds the switch number entry to an attached switch; when read, 0 is returned.
Identification
{1 3 6 1 4 1 26543 2 7 7 12 1 1 2 1 4}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In LENOVO-GbTOR-G8052-RS-MIB, the row index switchNumberNewCfg is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.26543.2.7.7.12.1.1.2.1.4.<switchNumberNewCfg>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.26543.2.7.7.12.1.1.2.1.4
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
switchBindToAttachedNewCfg OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When written, binds the switch number entry to an attached switch;
when read, 0 is returned."
::= { switchNumNewCfgEntry 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
When written, binds the switch number entry to an attached switch; when read, 0 is returned.
IBM MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: switchBindToAttachedNewCfg
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"switchBindToAttachedNewCfg",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"When written, binds the switch number entry to an attached switch; when read, 0 is returned.\"",
"::=",
"{",
"switchNumNewCfgEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"When written, binds the switch number entry to an attached switch; when read, 0 is returned."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. IBM support.
Module: LENOVO-GbTOR-G8052-RS-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'MacAddress', 'TruthValue', 'RowStatus', 'TEXTUAL-CONVENTION', 'TruthValue', 'DisplayString', 'PhysAddress', 'MacAddress', 'RowStatus', 'TimeInterval', 'TimeStamp', 'RowPointer', 'AutonomousType', 'StorageType', 'TDomain', 'TAddress'], 'BRIDGE-MIB': ['BridgeId', 'BridgeId', 'dot1dTp', 'dot1dTpPort', 'dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'Gauge32', 'Counter64', 'TimeTicks', 'IpAddress', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Integer32', 'Unsigned32', 'Counter32', 'Gauge32', 'Counter64', 'TimeTicks', 'IpAddress', 'mib-2'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['sysName', 'sysLocation', 'sysContact', 'ifIndex', 'sysName', 'sysLocation', 'sysContact', 'ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpMessageProcessingModel', 'SnmpSecurityModel', 'SnmpSecurityLevel'], 'SNMP-USER-BASED-SM-MIB': ['usmNoAuthProtocol', 'usmNoPrivProtocol']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.26543.2.7.7.12.1.1.2.1.1 | switchNumberNewCfg | 0 | 0 | |
| 1.3.6.1.4.1.26543.2.7.7.12.1.1.2.1.2 | switchMACNewCfg | 0 | 0 | |
| 1.3.6.1.4.1.26543.2.7.7.12.1.1.2.1.5 | switchDeleteNewCfg | 0 | 0 | |
| 1.3.6.1.4.1.26543.2.7.7.12.1.1.2.1.7 | switchDescrNewCfg | 0 | 0 |