OID reference

msdpMeshGroupStatus

1.3.6.1.4.1.272.4.5.56.1.1.7.1.3

Description

This entry's status, by which new entries may be added to the table and old entries deleted. msdpMeshGroupName and msdpMeshGroupPeerAddress must be set to valid values before the row can be activated. Since these are the table's INDEX, a row can be activated by simply setting the msdpMeshGroupStatus variable. It is no…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.272.4.5.56.1.1.7.1 (msdpMeshGroupEntry)
Node code
3
Node name
msdpMeshGroupStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.272.4.5.56.1.1.7.1.3
URN notation
urn:oid:1.3.6.1.4.1.272.4.5.56.1.1.7.1.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 272 4 5 56 1 1 7 1 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) bintec(272) bibo(4) biboip(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) bintec(272) bibo(4) biboipold(5) msdpMIB(56) msdpMIBobjects(1) msdp(1) msdpMeshGroupTable(7) msdpMeshGroupEntry(1) msdpMeshGroupStatus(3)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/272/4/5/56/1/1/7/1/3
  • /ISO/Identified-Organization/6/1/4/1/272/4/5/56/1/1/7/1/3
  • /ISO/3/6/1/4/1/272/4/5/56/1/1/7/1/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/identified-organization/dod/internet/private/enterprise/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/identified-organization/dod/internet/private/enterprises/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/identified-organization/dod/internet/private/enterprises/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/enterprise/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/enterprise/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/enterprises/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/enterprises/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/ldap-enterprise/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/ldap-enterprise/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/vendor-objects/bintec/bibo/biboip/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • /iso/org/dod/internet/private/vendor-objects/bintec/bibo/biboipold/msdpMIB/msdpMIBobjects/msdp/msdpMeshGroupTable/msdpMeshGroupEntry/msdpMeshGroupStatus
  • Additional combinations skipped.

SNMP properties

Value type
RowStatus
Maximum access defined by MIB
read-write
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

msdpMeshGroupStatus OBJECT-TYPE
    SYNTAX     RowStatus
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
               "This entry's status, by which new entries may be added
               to the table and old entries deleted.

               msdpMeshGroupName and msdpMeshGroupPeerAddress must be
               set to valid values before the row can be activated.
               Since these are the table's INDEX, a row can be activated
               by simply setting the msdpMeshGroupStatus variable.

               It is not possible to modify other columns in the same
               conceptual row when the status value is active(1),
               because the only other objects in the row are part of the
               INDEX.  Changing one of these changes the row, so an old
               row must be deleted and a new one created."
       ::= { msdpMeshGroupEntry 3 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This entry's status, by which new entries may be added to the table and old entries deleted. msdpMeshGroupName and msdpMeshGroupPeerAddress must be set to valid values before the row can be activated. Since these are the table's INDEX, a row can be activated by simply setting the msdpMeshGroupStatus variable. It is not possible to modify other columns in the same conceptual row when the status value is active(1), because the only other objects in the row are part of the INDEX. Changing one of these changes the row, so an old row must be deleted and a new one created.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

msdpMeshGroupStatus · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: msdpMeshGroupStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "msdpMeshGroupStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "RowStatus",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This entry's status, by which new entries may be added to the table and old entries deleted. msdpMeshGroupName and msdpMeshGroupPeerAddress must be set to valid values before the row can be activated. Since these are the table's INDEX, a row can be activated by simply setting the msdpMeshGroupStatus variable. It is not possible to modify other columns in the same conceptual row when the status value is active(1), because the only other objects in the row are part of the INDEX. Changing one of these changes the row, so an old row must be deleted and a new one created.\"",
    "::=",
    "{",
    "msdpMeshGroupEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "RowStatus"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This entry's status, by which new entries may be added to the table and old entries deleted. msdpMeshGroupName and msdpMeshGroupPeerAddress must be set to valid values before the row can be activated. Since these are the table's INDEX, a row can be activated by simply setting the msdpMeshGroupStatus variable. It is not possible to modify other columns in the same conceptual row when the status value is active(1), because the only other objects in the row are part of the INDEX. Changing one of these changes the row, so an old row must be deleted and a new one created."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.272)

Hertlein Elisabeth

Siblings (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.272.4.5.56.1.1.7.1.1 msdpMeshGroupName00
1.3.6.1.4.1.272.4.5.56.1.1.7.1.2 msdpMeshGroupPeerAddress00