LMI monitored event count for DCE interface. For DTE, value becomes zero (0).
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.12
LMI monitored event count for DCE interface. For DTE, value becomes zero (0).
Identification
{1 3 6 1 4 1 27514 1 1 10 2 50 1 1 1 1 12}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published AUGMENTS row: frDlcmiEntry. Check that row's index definition for the instance suffix.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.12
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
qtechfrLmiN393Dce OBJECT-TYPE
SYNTAX INTEGER (0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LMI monitored event count for DCE interface.
For DTE, value becomes zero (0)."
::= { qtechfrLmiEntry 12 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
LMI monitored event count for DCE interface. For DTE, value becomes zero (0).
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: qtechfrLmiN393Dce
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"qtechfrLmiN393Dce",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"10",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"LMI monitored event count for DCE interface. For DTE, value becomes zero (0).\"",
"::=",
"{",
"qtechfrLmiEntry",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
10
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"LMI monitored event count for DCE interface. For DTE, value becomes zero (0)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: QTECH-FRAME-RELAY-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'QTECH-SMI': ['qtechMgmt'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'Integer32', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FRAME-RELAY-DTE-MIB': ['frDlcmiEntry', 'frCircuitEntry', 'frCircuitIfIndex', 'frCircuitDlci']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.1 | qtechfrLmiLinkstatus | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.2 | qtechfrLmiLinkType | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.3 | qtechfrLmiEnquiryIns | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.4 | qtechfrLmiEnquiryOuts | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.5 | qtechfrLmiStatusIns | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.6 | qtechfrLmiStatusOuts | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.7 | qtechfrLmiUpdateStatusIns | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.8 | qtechfrLmiUpdateStatusOuts | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.9 | qtechfrLmiStatusTimeouts | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.10 | qtechfrLmiStatusEnqTimeouts | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.11 | qtechfrLmiN392Dce | 0 | 0 | |
| 1.3.6.1.4.1.27514.1.1.10.2.50.1.1.1.1.13 | qtechfrLmiT392Dce | 0 | 0 |