Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rmonHistoryControlInterval",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"3600",
")",
"UNITS",
[
"literal",
"225365636f6e647322"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this rmonHistoryControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket may overflow at their maximum value with no indication, a prudent manager will take into account the possibility of overflow in any of the associated counters. It is important to consider the minimum time in which any counter could overflow on a particular media type and set the rmonHistoryControlInterval object to a value less than this interval. This is typically most important for the 'octets' counter in any media-specific table. For example, on an Ethernet network, the rmonEtherHistoryOctets counter could overflow in about one hour at the Ethernet's maximum utilization. This object may not be modified if the associated rmonHistoryControlStatus object is equal to valid(1).\"",
"DEFVAL",
"{",
"1800",
"}",
"::=",
"{",
"rmonHistoryControlEntry",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
3600
]
]
]
],
[
"UNITS",
"Seconds"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this rmonHistoryControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket may overflow at their maximum value with no indication, a prudent manager will take into account the possibility of overflow in any of the associated counters. It is important to consider the minimum time in which any counter could overflow on a particular media type and set the rmonHistoryControlInterval object to a value less than this interval. This is typically most important for the 'octets' counter in any media-specific table. For example, on an Ethernet network, the rmonEtherHistoryOctets counter could overflow in about one hour at the Ethernet's maximum utilization. This object may not be modified if the associated rmonHistoryControlStatus object is equal to valid(1)."
],
null,
null,
null,
[
"DEFVAL",
1800
]
]
}