gm2LoopdetectCtrlInterval — APRESIA official small-business switch MIB packages
This object indicates the interval value. The range is from 1 to 32767 seconds.
{1 3 6 1 4 1 278 109 2 4 1 1 2}
This object indicates the interval value. The range is from 1 to 32767 seconds.
ループ検知機能の検知フレーム送信間隔(秒)を示します。
Status in source: current.
Names: gm2LoopdetectCtrlInterval
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"gm2LoopdetectCtrlInterval",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"1",
".",
".",
"32767",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object indicates the interval value. The range is from 1 to 32767 seconds.\"",
"DEFVAL",
"{",
"10",
"}",
"::=",
"{",
"gm2LoopDetectCtrl",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
1,
32767
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object indicates the interval value. The range is from 1 to 32767 seconds."
],
null,
null,
null,
[
"DEFVAL",
10
]
]
}Module: APLGM200MIB
gm2LoopdetectCtrlInterval OBJECT-TYPE
SYNTAX INTEGER (1..32767)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the interval value. The range is from 1 to 32767 seconds."
DEFVAL {10}
::= { gm2LoopDetectCtrl 2 }{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['MacAddress', 'RowStatus', 'DisplayString'], 'SNMPv2-MIB': ['sysDescr', 'sysObjectID'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'NOTIFICATION-TYPE', 'Integer32', 'Gauge32', 'IpAddress', 'TimeTicks'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['mib-2', 'ifIndex', 'PhysAddress', 'sysDescr', 'sysObjectID', 'sysObjectID'], 'Q-BRIDGE-MIB': ['dot1qVlanIndex', 'PortList'], 'IEEE8023-LAG-MIB': ['dot3adAggActorAdminKey']}Source data warning: The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.
· Download APRESIA official MIB — APLGM200-mibs_104.zip / APLGM200-mibs.mibRelated source files and packages:
The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.; Publisher path: support/manual/image/APLGM200-mibs_104.zip; 83,940 bytes
Downloaded: 2026-11-03T01:07:30.963126+00:00.
Module: APLGM200MIB
gm2LoopdetectCtrlInterval OBJECT-TYPE
SYNTAX INTEGER (1..32767)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the interval value. The range is from 1 to 32767 seconds."
DEFVAL {10}
::= { gm2LoopDetectCtrl 2 }{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['MacAddress', 'RowStatus', 'DisplayString'], 'SNMPv2-MIB': ['sysDescr', 'sysObjectID'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'NOTIFICATION-TYPE', 'Integer32', 'Gauge32', 'IpAddress', 'TimeTicks'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['mib-2', 'ifIndex', 'PhysAddress', 'sysDescr', 'sysObjectID', 'sysObjectID'], 'Q-BRIDGE-MIB': ['dot1qVlanIndex', 'PortList'], 'IEEE8023-LAG-MIB': ['dot3adAggActorAdminKey']}Source data warning: The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.
· Download APRESIA official MIB — APLGM200-mibs_105.zip / APLGM200-mibs.mibRelated source files and packages:
The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.; File: APLGM200-mibs_105/APLGM200-mibs.mib; Publisher path: support/manual/image/APLGM200-mibs_105.zip; 83,604 bytes
Downloaded: 2026-11-03T01:07:32.168110+00:00.
Status in source: unspecified.
Names: gm2LoopDetectCtrlInterval, gm2LoopdetectCtrlInterval
{
"definition": [
"・",
"gm2LoopDetectCtrlInterval",
"(",
"1",
".",
"3",
".",
"6",
".",
"1",
".",
"4",
".",
"1",
".",
"278",
".",
"109",
".",
"2",
".",
"4",
".",
"1",
".",
"1",
".",
"2",
")",
"シ",
"ン",
"タ",
"ッ",
"ク",
"ス",
"INTEGER",
"(",
"1",
".",
".",
"32767",
")",
"ア",
"ク",
"セ",
"ス",
"read-write",
"定",
"義",
"ル",
"ー",
"プ",
"検",
"知",
"機",
"能",
"の",
"検",
"知",
"フ",
"レ",
"ー",
"ム",
"送",
"信",
"間",
"隔",
"(",
"秒",
")",
"を",
"示",
"し",
"ま",
"す",
"。"
]
}Module: APLGM200MIB
・ gm2LoopDetectCtrlInterval(1.3.6.1.4.1.278.109.2.4.1.1.2)
シンタックス INTEGER (1..32767)
アクセス read-write
定義 ループ検知機能の検知フレーム送信間隔(秒)を示します。Source data warning: The official manual's detailed object table explicitly states this OID; the companion MIB declares the same numeric value. The manual's overview tree inconsistently prints 1.3.6.1.4.1.278.1.109 instead of 1.3.6.1.4.1.278.109. No alternate numeric paths are inferred from that diagram.
Source data warning: The manual labels this OID gm2LoopDetectCtrlInterval, while the companion official MIB labels the same numeric value gm2LoopdetectCtrlInterval. Both published names are retained.
· Download APRESIA GM200 v2.03 — official MIB implementation manualRelated source files and packages:
Downloaded: 2026-11-03T01:16:30.092182+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.278.109.2.4.1.1.1 | gm2LoopdetectCtrlState, gm2LoopDetectCtrlState | 0 | 0 |