gm2LoopDetectCtrlPortMethod, gm2LoopdetectPortMethod — APRESIA GM200 official detailed MIB manual
ポートのループ検知機能のアクションを示します。
{1 3 6 1 4 1 278 109 2 4 1 2 1 3}
ポートのループ検知機能のアクションを示します。
This object indicates what method will be used when loop detected on the port.
Status in source: unspecified.
Names: gm2LoopDetectCtrlPortMethod, gm2LoopdetectPortMethod
{
"definition": [
"・",
"gm2LoopDetectCtrlPortMethod",
"(",
"1",
".",
"3",
".",
"6",
".",
"1",
".",
"4",
".",
"1",
".",
"278",
".",
"109",
".",
"2",
".",
"4",
".",
"1",
".",
"2",
".",
"1",
".",
"3",
")",
"シ",
"ン",
"タ",
"ッ",
"ク",
"ス",
"INTEGER",
"ア",
"ク",
"セ",
"ス",
"read-write",
"定",
"義",
"ポ",
"ー",
"ト",
"の",
"ル",
"ー",
"プ",
"検",
"知",
"機",
"能",
"の",
"ア",
"ク",
"シ",
"ョ",
"ン",
"を",
"示",
"し",
"ま",
"す",
"。"
]
}Module: APLGM200MIB
・ gm2LoopDetectCtrlPortMethod(1.3.6.1.4.1.278.109.2.4.1.2.1.3)
シンタックス INTEGER
アクセス read-write
定義 ポートのループ検知機能のアクションを示します。Source data warning: The official manual's detailed object table explicitly states this OID; the companion MIB declares the same numeric value. The manual's overview tree inconsistently prints 1.3.6.1.4.1.278.1.109 instead of 1.3.6.1.4.1.278.109. No alternate numeric paths are inferred from that diagram.
Source data warning: The manual labels this OID gm2LoopDetectCtrlPortMethod, while the companion official MIB labels the same numeric value gm2LoopdetectPortMethod. Both published names are retained.
· Download APRESIA GM200 v2.03 — official MIB implementation manualRelated source files and packages:
Downloaded: 2026-11-03T01:16:30.092182+00:00.
Status in source: current.
Names: gm2LoopdetectPortMethod
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"gm2LoopdetectPortMethod",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"notify-only",
"(",
"1",
")",
",",
"shutdown",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object indicates what method will be used when loop detected on the port.\"",
"::=",
"{",
"gm2LoopDetectPortMgmtEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"notify-only",
1
],
[
"shutdown",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object indicates what method will be used when loop detected on the port."
],
null,
null,
null,
null
]
}Module: APLGM200MIB
gm2LoopdetectPortMethod OBJECT-TYPE
SYNTAX INTEGER {
notify-only(1),
shutdown(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates what method will be used when loop detected on the port."
::= { gm2LoopDetectPortMgmtEntry 3 }{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['MacAddress', 'RowStatus', 'DisplayString'], 'SNMPv2-MIB': ['sysDescr', 'sysObjectID'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'NOTIFICATION-TYPE', 'Integer32', 'Gauge32', 'IpAddress', 'TimeTicks'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['mib-2', 'ifIndex', 'PhysAddress', 'sysDescr', 'sysObjectID', 'sysObjectID'], 'Q-BRIDGE-MIB': ['dot1qVlanIndex', 'PortList'], 'IEEE8023-LAG-MIB': ['dot3adAggActorAdminKey']}Source data warning: The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.
· Download APRESIA official MIB — APLGM200-mibs_104.zip / APLGM200-mibs.mibRelated source files and packages:
The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.; Publisher path: support/manual/image/APLGM200-mibs_104.zip; 83,940 bytes
Downloaded: 2026-11-03T01:07:30.963126+00:00.
Module: APLGM200MIB
gm2LoopdetectPortMethod OBJECT-TYPE
SYNTAX INTEGER {
notify-only(1),
shutdown(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates what method will be used when loop detected on the port."
::= { gm2LoopDetectPortMgmtEntry 3 }{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['MacAddress', 'RowStatus', 'DisplayString'], 'SNMPv2-MIB': ['sysDescr', 'sysObjectID'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'NOTIFICATION-TYPE', 'Integer32', 'Gauge32', 'IpAddress', 'TimeTicks'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['mib-2', 'ifIndex', 'PhysAddress', 'sysDescr', 'sysObjectID', 'sysObjectID'], 'Q-BRIDGE-MIB': ['dot1qVlanIndex', 'PortList'], 'IEEE8023-LAG-MIB': ['dot3adAggActorAdminKey']}Source data warning: The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.
· Download APRESIA official MIB — APLGM200-mibs_105.zip / APLGM200-mibs.mibRelated source files and packages:
The official GM200 MIB defines its management branch under 1.3.6.1.4.1.278.109. The linked GM200 v2.03 manual prints 1.3.6.1.4.1.278.1.109 in its overview tree, but its detailed object tables independently agree with the MIB on 1.3.6.1.4.1.278.109. Both official documents are available for comparison; device and firmware behaviour is unconfirmed.; File: APLGM200-mibs_105/APLGM200-mibs.mib; Publisher path: support/manual/image/APLGM200-mibs_105.zip; 83,604 bytes
Downloaded: 2026-11-03T01:07:32.168110+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.278.109.2.4.1.2.1.1 | gm2LoopdetectPortIndex, gm2LoopDetectCtrlPortIndex | 0 | 0 | |
| 1.3.6.1.4.1.278.109.2.4.1.2.1.2 | gm2LoopdetectPortState, gm2LoopDetectCtrlPortState | 0 | 0 | |
| 1.3.6.1.4.1.278.109.2.4.1.2.1.4 | gm2LoopdetectPortLoopStatus, gm2LoopDetectCtrlPortLoopStatus | 0 | 0 |