hclMmrpPlusUplinkforcedownMethod — APRESIA AEOS 8.45 official MIB implementation manual
Definition: 障害の発生と復旧により MMRP‑Plus が動作したとき、アップリンクポートを瞬断するモード の指定。unknown(1)は設定不可。 AEOS 8.45 implementation: read‑only 常に unknown(1)を返す。
{1 3 6 1 4 1 278 2 30 22 3 3 1 1 7}
Definition: 障害の発生と復旧により MMRP‑Plus が動作したとき、アップリンクポートを瞬断するモード の指定。unknown(1)は設定不可。 AEOS 8.45 implementation: read‑only 常に unknown(1)を返す。
Status in source: current.
Names: hclMmrpPlusUplinkforcedownMethod
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hclMmrpPlusUplinkforcedownMethod",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"unknown",
"(",
"1",
")",
",",
"autoNegoRestert",
"(",
"2",
")",
",",
"phyStop",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"\"",
"::=",
"{",
"hclMmrpPlusRingEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"unknown",
1
],
[
"autoNegoRestert",
2
],
[
"phyStop",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
""
],
null,
null,
null,
null
]
}Module: Apresia-Series
hclMmrpPlusUplinkforcedownMethod OBJECT-TYPE
SYNTAX INTEGER {
unknown(1), -- DefaultValue
autoNegoRestert(2),
phyStop(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION ""
::= { hclMmrpPlusRingEntry 7 }{'IF-MIB': ['ifIndex', 'ifAdminStatus', 'ifOperStatus', 'InterfaceIndex', 'ifDescr'], 'RMON2-MIB': ['TimeFilter'], 'SNMPv2-TC': ['RowStatus', 'DisplayString', 'TimeStamp', 'MacAddress', 'PhysAddress'], 'SNMPv2-MIB': ['sysDescr', 'sysObjectID'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Counter32', 'Integer32', 'Gauge32', 'IpAddress', 'TimeTicks', 'Unsigned32', 'Counter64'], 'IEEE8023-LAG-MIB': ['dot3adAggActorAdminKey']}Related source files and packages:
Downloaded: 2026-11-03T01:21:57.291994+00:00.
Status in source: unspecified.
Names: hclMmrpPlusUplinkforcedownMethod
{
"definition": [
"4",
".",
"6",
".",
"3",
".",
"8",
"hclMmrpPlusUplinkforcedownMethod",
"(",
"1",
".",
"3",
".",
"6",
".",
"1",
".",
"4",
".",
"1",
".",
"278",
".",
"2",
".",
"30",
".",
"22",
".",
"3",
".",
"3",
".",
"1",
".",
"1",
".",
"7",
")",
"定",
"義",
"障",
"害",
"の",
"発",
"生",
"と",
"復",
"旧",
"に",
"よ",
"り",
"MMRP",
"‑",
"Plus",
"が",
"動",
"作",
"し",
"た",
"と",
"き",
"、",
"ア",
"ッ",
"プ",
"リ",
"ン",
"ク",
"ポ",
"ー",
"ト",
"を",
"瞬",
"断",
"す",
"る",
"モ",
"ー",
"ド",
"の",
"指",
"定",
"。",
"unknown",
"(",
"1",
")",
"は",
"設",
"定",
"不",
"可",
"。",
"実",
"装",
"read",
"‑",
"only",
"常",
"に",
"unknown",
"(",
"1",
")",
"を",
"返",
"す",
"。"
]
}Module: AEOS-8.45
4.6.3.8 hclMmrpPlusUplinkforcedownMethod(1.3.6.1.4.1.278.2.30.22.3.3.1.1.7) 定義 障害の発生と復旧により MMRP‑Plus が動作したとき、アップリンクポートを瞬断するモード の指定。unknown(1)は設定不可。 実装 read‑only 常に unknown(1)を返す。
Source data warning: Implementation notes apply to APRESIA AEOS version 8.45 and its documented devices; other implementations may differ.
· Download APRESIA AEOS 8.45 — official MIB implementation manualRelated source files and packages:
Downloaded: 2026-11-03T01:35:07.298002+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.1 | hclMmrpPlusRingIndex | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.2 | hclMmrpPlusRingRowStatus | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.3 | hclMmrpPlusRingName | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.4 | hclMmrpPlusRingVlanGroupIndex | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.5 | hclMmrpPlusVid | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.6 | hclMmrpPlusUplinkMap | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.8 | hclMmrpPlusUplinkforcedownTime | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.9 | hclMmrpPlusUplinkforcedownUpWait | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.10 | hclMmrpPlusListeningTimer | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.11 | hclMmrpPlusFDBFlushTimer | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.12 | hclMmrpPlusAdminStatus | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.13 | hclMmrpPlusRingRevertiveMode | 0 | 0 | |
| 1.3.6.1.4.1.278.2.30.22.3.3.1.1.14 | hclMmrpPlusRingRevertiveTime | 0 | 0 |