Description 1
This should always write running-config to startup-config.And the valid set value is 1. When get the configSave value, 1 means success, 0 means failure.
Sources for this description
FS.COM MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.27975.1.3.1
This should always write running-config to startup-config.And the valid set value is 1. When get the configSave value, 1 means success, 0 means failure.
Identification
{1 3 6 1 4 1 27975 1 3 1}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.27975.1.3.1.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The FS.COM catalogue lists MIB packages containing this definition for these models:
A definition in a model's MIB package does not establish that the device implements it or permits access.
Available source records contain 2 distinct definitions; some records may not include a definition.
configSave OBJECT-TYPE
SYNTAX Integer32 (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This should always write running-config to startup-config.And the
valid set value is 1. When get the configSave value, 1 means success, 0 means failure."
::= { operate 1 }configSave OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This should always write running-config to startup-config.And the
valid value is 1."
::= { operate 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
This should always write running-config to startup-config.And the valid set value is 1. When get the configSave value, 1 means success, 0 means failure.
FS.COM MIB copies (LibreNMS/Observium Community)
Description 2
This should always write running-config to startup-config.And the valid value is 1.
FS.COM official Documentation Hub native MIB packages
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: configSave
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"configSave",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This should always write running-config to startup-config.And the valid set value is 1. When get the configSave value, 1 means success, 0 means failure.\"",
"::=",
"{",
"operate",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This should always write running-config to startup-config.And the valid set value is 1. When get the configSave value, 1 means success, 0 means failure."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. FS.COM support.
Module: SWITCH
See published definition above
{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'InterfaceIndexOrZero', 'ifIndex'], 'RMON-MIB': ['OwnerString'], 'VRRP-MIB': ['VrId'], 'SNMPv2-TC': ['TestAndIncr', 'TimeStamp', 'AutonomousType', 'DisplayString', 'PhysAddress', 'TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['TimeTicks', 'Counter32', 'OBJECT-IDENTITY', 'mib-2', 'MODULE-IDENTITY', 'IpAddress', 'Counter64', 'Unsigned32', 'Integer32', 'Gauge32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. FS.COM support.
Module: FS-SWITCH-MIB
{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'InterfaceIndexOrZero', 'ifIndex'], 'RMON-MIB': ['OwnerString'], 'VRRP-MIB': ['VrId'], 'SNMPv2-TC': ['TestAndIncr', 'TimeStamp', 'AutonomousType', 'DisplayString', 'PhysAddress', 'TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['TimeTicks', 'Counter32', 'OBJECT-IDENTITY', 'mib-2', 'MODULE-IDENTITY', 'IpAddress', 'Counter64', 'Unsigned32', 'Integer32', 'Gauge32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Status in source: current.
Names: configSave
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"configSave",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This should always write running-config to startup-config.And the valid value is 1.\"",
"::=",
"{",
"operate",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This should always write running-config to startup-config.And the valid value is 1."
],
null,
null,
null,
null
]
}Module: CENTEC
See published definition above
{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'InterfaceIndexOrZero', 'ifIndex'], 'RMON-MIB': ['OwnerString'], 'VRRP-MIB': ['VrId'], 'SNMPv2-TC': ['TestAndIncr', 'TimeStamp', 'AutonomousType', 'PhysAddress', 'TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['TimeTicks', 'Counter32', 'OBJECT-IDENTITY', 'mib-2', 'MODULE-IDENTITY', 'IpAddress', 'Counter64', 'Unsigned32', 'Integer32', 'Gauge32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.27975.1.3.2 | reload | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.3 | rebootAt | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.4 | rebootDelay | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.5 | version | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.6 | serviceTelnet | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.7 | loginFail | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.8 | lastCommand | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.9 | currentRunningImage | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.10 | sysStartUpTime | 0 | 0 | |
| 1.3.6.1.4.1.27975.1.3.20 | resetToFactory | 0 | 0 |