TempBus1 Active Set Point Sensor Trap
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.29414.1.4.1.25
TempBus1 Active Set Point Sensor Trap
Identification
{1 3 6 1 4 1 29414 1 4 1 25}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ODS-MIB, the row index fancontrolIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.29414.1.4.1.25.<fancontrolIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.29414.1.4.1.25
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
fancontrolTempBus1 OBJECT-TYPE
SYNTAX Gauge32
UNITS "Disconnected External Sensor"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "TempBus1 Active Set Point Sensor Trap"
::= { fancontrolEntry 25 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
TempBus1 Active Set Point Sensor Trap
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: fancontrolTempBus1
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fancontrolTempBus1",
"OBJECT-TYPE",
"SYNTAX",
"Gauge32",
"UNITS",
[
"literal",
"22446973636f6e6e65637465642045787465726e616c2053656e736f7222"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"TempBus1 Active Set Point Sensor Trap\"",
"::=",
"{",
"fancontrolEntry",
"25",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge32"
],
[
"UNITS",
"Disconnected External Sensor"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"TempBus1 Active Set Point Sensor Trap"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: ODS-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Gauge32', 'NOTIFICATION-TYPE']}Related source files and packages:
Registration