OID reference

limitSupplyAirPrsureTooHighLimit

1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1729

Description

limit, supply air pressure too high limit

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1 (opCtrlAirEntry)
Node code
1729
Node name
limitSupplyAirPrsureTooHighLimit
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1729
URN notation
urn:oid:1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1729
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 29462 10 2 1 2 1 1 4 1 1729}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) stulz(29462) stulzWib(10) wibUnits(2) unitTypeAC(1) operation(2) opValuesControl(1) opCtrlAir(1) opCtrlAirTable(4) opCtrlAirEntry(1) limitSupplyAirPrsureTooHighLimit(1729)}
OID-IRI notation
  • /1/3/6/1/4/1/29462/10/2/1/2/1/1/4/1/1729
  • /ISO/Identified-Organization/6/1/4/1/29462/10/2/1/2/1/1/4/1/1729
  • /ISO/3/6/1/4/1/29462/10/2/1/2/1/1/4/1/1729
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/identified-organization/dod/internet/private/enterprise/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/identified-organization/dod/internet/private/enterprises/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/identified-organization/dod/internet/private/enterprises/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/identified-organization/dod/internet/private/vendor-objects/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/identified-organization/dod/internet/private/vendor-objects/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/enterprise/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/enterprise/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/enterprises/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/enterprises/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/ldap-enterprise/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/ldap-enterprise/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/vendor-objects/29462/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • /iso/org/dod/internet/private/vendor-objects/stulz/stulzWib/wibUnits/unitTypeAC/operation/opValuesControl/opCtrlAir/opCtrlAirTable/opCtrlAirEntry/limitSupplyAirPrsureTooHighLimit
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-write
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In Stulz-WIB8000-MIB, the row index consists of these components in order:

  1. wibBusNumber (Integer32): one numeric subidentifier for the non-negative value.
  2. wibDeviceAddress (Integer32): one numeric subidentifier for the non-negative value.
  3. wibModuleNumber (Integer32): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1729.<wibBusNumber>.<wibDeviceAddress>.<wibModuleNumber>. Use values present on the device and permitted by its MIB. Other definitions can differ.

For this example, the row inherits its index through AUGMENTS from wibIndexEntry in the same MIB.

Published AUGMENTS row: wibIndexEntry. Check that row's index definition for the instance suffix.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1729

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

limitSupplyAirPrsureTooHighLimit OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
		"limit, supply air pressure too high limit"
	::= { opCtrlAirEntry 1729 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

limit, supply air pressure too high limit

Sources for this description

Common and standard MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Common and standard MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

limitSupplyAirPrsureTooHighLimit · currentCommon and standard MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: limitSupplyAirPrsureTooHighLimit

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "limitSupplyAirPrsureTooHighLimit",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"limit, supply air pressure too high limit\"",
    "::=",
    "{",
    "opCtrlAirEntry",
    "1729",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "limit, supply air pressure too high limit"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.29462)

Michael Knecht

Siblings (11)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1730 limitSupplyAirPrsureTooHighDelay00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1731 limitSupplyAirPrTooHighDoutPrio00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1732 limitSupplyAirPrsureTooLowLimit00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1733 limitSupplyAirPrsureTooLowDelay00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1734 limitSupplyAirPrreTooLowDoutPrio00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1735 unitCurrentSupplyAirPressure00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1736 unitSetpointSupplyAirPressure00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1874 prealarmSupplyAiureTooHighLimit00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1875 prealarmSupplyAiooHighAlarmDelay00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1877 prealarmSupplyAissureTooLowLimit00
1.3.6.1.4.1.29462.10.2.1.2.1.1.4.1.1878 prealarmSupplyAiooLowAlarmDelay00