PWW-heating config active
Sources for this description
Common and standard MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.29462.10.2.1.3.2.2.3.1.1.6300
PWW-heating config active
Identification
{1 3 6 1 4 1 29462 10 2 1 3 2 2 3 1 1 6300}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In Stulz-WIB8000-MIB, the row index consists of these components in order:
wibBusNumber (Integer32): one numeric subidentifier for the non-negative value.wibDeviceAddress (Integer32): one numeric subidentifier for the non-negative value.wibModuleNumber (Integer32): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.29462.10.2.1.3.2.2.3.1.1.6300.<wibBusNumber>.<wibDeviceAddress>.<wibModuleNumber>. Use values present on the device and permitted by its MIB. Other definitions can differ.
For this example, the row inherits its index through AUGMENTS from wibIndexEntry in the same MIB.
Published AUGMENTS row: wibIndexEntry. Check that row's index definition for the instance suffix.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.29462.10.2.1.3.2.2.3.1.1.6300
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
pWWHeatingConfigActive OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PWW-heating config active"
::= { confHwrValveEntry 6300 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
PWW-heating config active
Common and standard MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: pWWHeatingConfigActive
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pWWHeatingConfigActive",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"PWW-heating config active\"",
"::=",
"{",
"confHwrValveEntry",
"6300",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"PWW-heating config active"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: Stulz-WIB8000-MIB
See published definition above
{'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.29462.10.2.1.3.2.2.3.1.1.6308 | pWWHeatingType | 0 | 0 | |
| 1.3.6.1.4.1.29462.10.2.1.3.2.2.3.1.1.6313 | pWWHeatingDigitalOut | 0 | 0 | |
| 1.3.6.1.4.1.29462.10.2.1.3.2.2.3.1.1.6314 | pWWHeatingAnalogOut | 0 | 0 |