been pressed since the variable was last read.
After this variable has been read it will be set to 0.
Sources for this description
MIBdepot
OID reference
1.3.6.1.4.1.295.3.2.1.1.1.11
This variable is TRUE (1) if the IDENTIFY button on the chassis has been pressed since the variable was last read. After this variable has been read it will be set to 0.
Identification
{1 3 6 1 4 1 295 3 2 1 1 1 11}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In SWITCH-MIB, the row index chassisIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.295.3.2.1.1.1.11.<chassisIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index variants: basicIndex; chassisIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.295.3.2.1.1.1.11
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
identPressed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is TRUE (1) if the IDENTIFY button on the chassis has
been pressed since the variable was last read.
After this variable has been read it will be set to 0."
::= { basicEntry 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
MIBdepot
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: identPressed
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"identPressed",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"This variable is TRUE (1) if the IDENTIFY button on the chassis has been pressed since the variable was last read. After this variable has been read it will be set to 0.\"",
"::=",
"{",
"basicEntry",
"11",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"This variable is TRUE (1) if the IDENTIFY button on the chassis has been pressed since the variable was last read. After this variable has been read it will be set to 0."
],
null,
null,
null,
null
]
}Module: SWITCH-MIB
See published definition above
{'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Counter', 'DisplayString']}Historical records
chassisIdentPressed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is TRUE (1) if the IDENTIFY button on the chassis has
been pressed since the variable was last read.
After this variable has been read it will be set to 0."
::= { chassisEntry 11 }
chassisIdentPressed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is TRUE (1) if the IDENTIFY button on the chassis has
been pressed since the variable was last read.
After this variable has been read it will be set to 0."
::= { chassisEntry 11 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.295.3.2.1.1.1.1 | productCode, chassisProductCode | 0 | 0 | An ASCII string giving the product code of the unit. |
| 1.3.6.1.4.1.295.3.2.1.1.1.2 | serialNumber, chassisSerialNumber | 0 | 0 | An ASCII string giving the unit's serial number. |
| 1.3.6.1.4.1.295.3.2.1.1.1.3 | placeOfManufacture, chassisPlaceOfManufacture | 0 | 0 | A number identifying where the unit was built. |
| 1.3.6.1.4.1.295.3.2.1.1.1.4 | dateOfManufacture, chassisDateOfManufacture | 0 | 0 | An ASCII string giving the date of manufacture of the unit. |
| 1.3.6.1.4.1.295.3.2.1.1.1.5 | macAddress, chassisMacAddress | 0 | 0 | The IEEE 802 MAC address of the unit. |
| 1.3.6.1.4.1.295.3.2.1.1.1.6 | codeVersion, chassisCodeVersion | 0 | 0 | An ASCII string giving the version number of the control software. |
| 1.3.6.1.4.1.295.3.2.1.1.1.7 | bpeEnabled, chassisBpeEnabled | 0 | 0 | Setting this variable to TRUE (1) causes the bridge protocol engine to perform the Spanning Tree Protocol as defined in IEEE802.… |
| 1.3.6.1.4.1.295.3.2.1.1.1.8 | eraseSnmpConfigInfo, chassisEraseSnmpConfigInfo | 0 | 0 | Setting this variable to TRUE (1) causes the unit to erase its SNMP configuration information both from memory and from permanen… |
| 1.3.6.1.4.1.295.3.2.1.1.1.9 | restoreDot1dDefaults, chassisRestoreDot1dDefaults | 0 | 0 | Setting this variable to TRUE (1) causes the BPE to restore the default spanning tree values given in the IEEE 802.1d specificat… |
| 1.3.6.1.4.1.295.3.2.1.1.1.10 | performReset, chassisPerformReset | 0 | 0 | Setting this variable to TRUE (1) causes the unit to perform a cold restart. As a result of this action a coldRestart trap will … |
| 1.3.6.1.4.1.295.3.2.1.1.1.12 | ageFilterDatabase, chassisAgeFilterDatabase | 0 | 0 | Setting this variable to FALSE (0) causes the unit to stop aging out entries from its filter database. Setting this variable to … |
| 1.3.6.1.4.1.295.3.2.1.1.1.13 | clearStatistics, chassisClearStatistics | 0 | 0 | Setting this variable to TRUE (1) clears the traffic statistics accumulators. Setting this variable to any other value has no e… |
| 1.3.6.1.4.1.295.3.2.1.1.1.14 | tcpKeepAlivesEnabled, chassisTcpKeepAlivesEnabled | 0 | 0 | Setting this variable to TRUE (1) causes keep alive packets to be transmitted on an idle TCP connection. The period of the keep… |
| 1.3.6.1.4.1.295.3.2.1.1.1.15 | tcpKeepAlivePeriod, chassisTcpKeepAlivePeriod | 0 | 0 | This variable defines the time period in seconds between keep alive packets transmitted on an idle TCP connection. This value m… |
| 1.3.6.1.4.1.295.3.2.1.1.1.16 | chassisTrafficAnalyzerPort | 0 | 0 | This variable specifies the traffic analyzer port (TAP) number. The TAP is the port which will transmit all frames received (i.… |
| 1.3.6.1.4.1.295.3.2.1.1.1.17 | chassisRepeaterSelector | 0 | 0 | This variable specifies the interface number of an option slot containing a repeater feature module. This variable identifies th… |
| 1.3.6.1.4.1.295.3.2.1.1.1.18 | chassisBackplaneFrameLossIncidents | 0 | 0 | The number of incidents of one or more frames not forwarded to the backplane due to lack of resources. |
| 1.3.6.1.4.1.295.3.2.1.1.1.19 | chassisHardwareFunctionDescriptor | 0 | 0 | An ASCII string giving the hardware type and revision of the fixed board |
| 1.3.6.1.4.1.295.3.2.1.1.1.100 | basicIndex, chassisIndex | 0 | 0 | This is a dummy variable which provides a meta-index for the Chassis Information Table. |