Status in source: current.
Names: issAclTrcFlag
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"issAclTrcFlag",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"255",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is used to enable trace statements in Acl module. A four byte integer is used for enabling the trace level. Each bit in the four byte integer represents a particular trace level. The mapping between the bit positions & the trace level is as follows: 0 - Init and Shutdown traces 1 - Management traces 2 - Data Path traces 3 - Control Plane traces 5 - Traces related to all resources except buffers 6 - Buffer allocation/release traces 7 - All Failure traces None of the bit is set the Disable the Trace,value(0). The remaining bits are unused. Combination of levels are also allowed. For example if the bits 0 and 1 are set, then the trace statement related to Init-Shutdown and management will be printed. The user has to enter the corresponding integer value for the bits set. For example if bits 0 and 1 are to be set ,then user has to give the value 3.\"",
"::=",
"{",
"issAclTrc",
"1",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is used to enable trace statements in Acl module. A four byte integer is used for enabling the trace level. Each bit in the four byte integer represents a particular trace level. The mapping between the bit positions & the trace level is as follows: 0 - Init and Shutdown traces 1 - Management traces 2 - Data Path traces 3 - Control Plane traces 5 - Traces related to all resources except buffers 6 - Buffer allocation/release traces 7 - All Failure traces None of the bit is set the Disable the Trace,value(0). The remaining bits are unused. Combination of levels are also allowed. For example if the bits 0 and 1 are set, then the trace statement related to Init-Shutdown and management will be printed. The user has to enter the corresponding integer value for the bits set. For example if bits 0 and 1 are to be set ,then user has to give the value 3."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: ARICENT-ISS-ACL-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'MacAddress', 'DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'enterprises', 'Integer32', 'Unsigned32'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}
· Download ARICENT-ISS-ACL-MIB
Related source files and packages: