Description 1
Configuring this value as true will make the clock to behave as slave clock. A boundary clock can not be a slave only clock.
Sources for this description
Belden, GarrettCom and Hirschmann IT official standalone MIBs
OID reference
1.3.6.1.4.1.29601.2.45.1.3.1.1.9
Configuring this value as true will make the clock to behave as slave clock. A boundary clock can not be a slave only clock.
Identification
{1 3 6 1 4 1 29601 2 45 1 3 1 1 9}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
fsPtpClockSlaveOnly OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configuring this value as true will make the clock to behave as slave
clock.
A boundary clock can not be a slave only clock."
DEFVAL { false }
::= { fsPtpClockDataSetEntry 9 }fsPtpClockSlaveOnly OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configuring this value as true will make the clock to behave as slave
clock.
A boundary clock cannot be a slave only clock."
DEFVAL { false }
::= { fsPtpClockDataSetEntry 9 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Configuring this value as true will make the clock to behave as slave clock. A boundary clock can not be a slave only clock.
Belden, GarrettCom and Hirschmann IT official standalone MIBs
Description 2
Configuring this value as true will make the clock to behave as slave clock. A boundary clock cannot be a slave only clock.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: fsPtpClockSlaveOnly
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsPtpClockSlaveOnly",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Configuring this value as true will make the clock to behave as slave clock. A boundary clock can not be a slave only clock.\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"fsPtpClockDataSetEntry",
"9",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Configuring this value as true will make the clock to behave as slave clock. A boundary clock can not be a slave only clock."
],
null,
null,
null,
[
"DEFVAL",
"false"
]
]
}Module: ARICENT-PTP-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'enterprises', 'NOTIFICATION-TYPE']}Related source files and packages:
Status in source: current.
Names: fsPtpClockSlaveOnly
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsPtpClockSlaveOnly",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Configuring this value as true will make the clock to behave as slave clock. A boundary clock cannot be a slave only clock.\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"fsPtpClockDataSetEntry",
"9",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Configuring this value as true will make the clock to behave as slave clock. A boundary clock cannot be a slave only clock."
],
null,
null,
null,
[
"DEFVAL",
"false"
]
]
}Vendor MIB copy from the Observium Community archive.
Module: ARICENT-PTP-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'enterprises', 'NOTIFICATION-TYPE']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.1 | fsPtpClockIdentity | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.2 | fsPtpClockTwoStepFlag | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.3 | fsPtpClockNumberPorts | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.4 | fsPtpClockClass | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.5 | fsPtpClockAccuracy | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.6 | fsPtpClockOffsetScaledLogVariance | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.7 | fsPtpClockPriority1 | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.8 | fsPtpClockPriority2 | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.10 | fsPtpClockPathTraceOption | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.11 | fsPtpClockAccMasterMaxSize | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.12 | fsPtpClockSecurityEnabled | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.45.1.3.1.1.13 | fsPtpClockNumOfSA | 0 | 0 |