Description 1
The Loopback Message table entry.
Sources for this description
Belden, GarrettCom and Hirschmann IT official standalone MIBs
OID reference
1.3.6.1.4.1.29601.2.7.1.2.7.1
The Loopback Message table entry.
Identification
{1 3 6 1 4 1 29601 2 7 1 2 7 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
fsMIY1731LbmEntry OBJECT-TYPE
SYNTAX FsMIY1731LbmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Loopback Message table entry."
INDEX { fsMIY1731ContextId,
fsMIY1731MegIndex,
fsMIY1731MeIndex,
fsMIY1731MepIdentifier,
fsMIY1731LbmTransId,
fsMIY1731LbmSeqNumber
}
::= { fsMIY1731LbmTable 1 }fsMIY1731LbmEntry OBJECT-TYPE
SYNTAX FsMIY1731LbmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the Loopback Message table entry."
INDEX { fsMIY1731ContextId,
fsMIY1731MegIndex,
fsMIY1731MeIndex,
fsMIY1731MepIdentifier,
fsMIY1731LbmTransId,
fsMIY1731LbmSeqNumber
}
::= { fsMIY1731LbmTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The Loopback Message table entry.
Belden, GarrettCom and Hirschmann IT official standalone MIBs
Description 2
This object specifies the Loopback Message table entry.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: fsMIY1731LbmEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsMIY1731LbmEntry",
"OBJECT-TYPE",
"SYNTAX",
"FsMIY1731LbmEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The Loopback Message table entry.\"",
"INDEX",
"{",
"fsMIY1731ContextId",
",",
"fsMIY1731MegIndex",
",",
"fsMIY1731MeIndex",
",",
"fsMIY1731MepIdentifier",
",",
"fsMIY1731LbmTransId",
",",
"fsMIY1731LbmSeqNumber",
"}",
"::=",
"{",
"fsMIY1731LbmTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"FsMIY1731LbmEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The Loopback Message table entry."
],
null,
null,
[
"INDEX",
[
[
0,
"fsMIY1731ContextId"
],
[
0,
"fsMIY1731MegIndex"
],
[
0,
"fsMIY1731MeIndex"
],
[
0,
"fsMIY1731MepIdentifier"
],
[
0,
"fsMIY1731LbmTransId"
],
[
0,
"fsMIY1731LbmSeqNumber"
]
]
],
null
]
}Module: ARICENT-ECFM-Y1731-MI-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'ECFM-MIB': ['Dot1agCfmMepId', 'Dot1agCfmTransmitStatus', 'Dot1agCfmMDLevelOrNone', 'Dot1agCfmMepIdOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'DisplayString', 'TimeInterval', 'TimeStamp', 'MacAddress', 'RowStatus', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32']}Related source files and packages:
Status in source: current.
Names: fsMIY1731LbmEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsMIY1731LbmEntry",
"OBJECT-TYPE",
"SYNTAX",
"FsMIY1731LbmEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This object specifies the Loopback Message table entry.\"",
"INDEX",
"{",
"fsMIY1731ContextId",
",",
"fsMIY1731MegIndex",
",",
"fsMIY1731MeIndex",
",",
"fsMIY1731MepIdentifier",
",",
"fsMIY1731LbmTransId",
",",
"fsMIY1731LbmSeqNumber",
"}",
"::=",
"{",
"fsMIY1731LbmTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"FsMIY1731LbmEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object specifies the Loopback Message table entry."
],
null,
null,
[
"INDEX",
[
[
0,
"fsMIY1731ContextId"
],
[
0,
"fsMIY1731MegIndex"
],
[
0,
"fsMIY1731MeIndex"
],
[
0,
"fsMIY1731MepIdentifier"
],
[
0,
"fsMIY1731LbmTransId"
],
[
0,
"fsMIY1731LbmSeqNumber"
]
]
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: ARICENT-ECFM-Y1731-MI-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'DisplayString', 'TimeInterval', 'TimeStamp', 'MacAddress', 'RowStatus', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32'], 'Q-BRIDGE-MIB': ['VlanId'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'Dot1agCfmMDLevelOrNone', 'Dot1agCfmMepIdOrZero']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.1 | fsMIY1731LbmTransId | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.2 | fsMIY1731LbmSeqNumber | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.3 | fsMIY1731LbmBytesSent | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.4 | fsMIY1731LbmTargetMacAddress | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.5 | fsMIY1731LbmUnexptedLbrIn | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.6 | fsMIY1731LbmDuplicatedLbrIn | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.7 | fsMIY1731LbmNumOfResponders | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.8 | fsMIY1731LbmDestType | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.9 | fsMIY1731LbmDestMepId | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.10 | fsMIY1731LbmIcc | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.11 | fsMIY1731LbmNodeId | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.12 | fsMIY1731LbmIfNum | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.7.1.2.7.1.13 | fsMIY1731LbmTTL | 0 | 0 |