This object contains the minimum value of far-end frame-loss.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.29601.2.71.7.5.1.7
This object contains the minimum value of far-end frame-loss.
Identification
{1 3 6 1 4 1 29601 2 71 7 5 1 7}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: fsMefContextId, fsMefMegIndex, fsMefMeIndex, fsMefMepIdentifier, fsMefFlTransId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.29601.2.71.7.5.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
fsMefFlStatsFarEndLossMin OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the minimum value of far-end frame-loss."
::= { fsMefFlStatsEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object contains the minimum value of far-end frame-loss.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: fsMefFlStatsFarEndLossMin
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsMefFlStatsFarEndLossMin",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This object contains the minimum value of far-end frame-loss.\"",
"::=",
"{",
"fsMefFlStatsEntry",
"7",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object contains the minimum value of far-end frame-loss."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: ARICENT-MEF-MIB
See published definition above
{'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'DisplayString', 'TimeInterval', 'TimeStamp', 'MacAddress'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Integer32', 'Gauge32', 'Unsigned32', 'Counter32', 'enterprises'], 'DIFFSERV-MIB': ['IndexInteger'], 'Q-BRIDGE-MIB': ['VlanId'], 'IANAifType-MIB': ['IANAifType'], 'ARICENT-QOS-MIB': ['MeterColorMode', 'MeterType'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'Dot1agCfmMepIdOrZero'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'ARICENT-ECFM-Y1731-MI-MIB': ['FsY1731TransmitStatus', 'FsY1731LmmInterval', 'FsY1731TimeRepresentation', 'FsY1731AvailabilityInterval', 'FsY1731AvailabilityType']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.29601.2.71.7.5.1.1 | fsMefFlStatsTimeStamp | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.2 | fsMefFlStatsMessagesOut | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.3 | fsMefFlStatsMessagesIn | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.4 | fsMefFlStatsFarEndLossAverage | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.5 | fsMefFlStatsNearEndLossAverage | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.6 | fsMefFlStatsMeasurementType | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.8 | fsMefFlStatsFarEndLossMax | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.9 | fsMefFlStatsNearEndLossMin | 0 | 0 | |
| 1.3.6.1.4.1.29601.2.71.7.5.1.10 | fsMefFlStatsNearEndLossMax | 0 | 0 |