Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsSynceIfConfigSwitch",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"none",
"(",
"0",
")",
",",
"forceSwitch",
"(",
"1",
")",
",",
"manualSwitch",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"When ForcedSwitch is enabled on an interface, it can override the currently selected synchronization source, provided the synchronization source is enabled and not locked out. The forced switch overrides the manual switch, and a subsequent forced switch pre-empts the previous forced switch.If the interface selected by the forced switch is disabled or locked out, the forced switch will be automatically rejected. A manual switch can be enabled on an interface provided the it is synce enabled, not locked out, not in signal fail condition, and has a QL better than DNU in QL-enabled mode. Furthermore, in QL-enabled mode, a manual switch can be performed only to a source which has the highest available QL. As such, these conditions have the effect that manual switching can only be used to override the assigned synchronization source priorities. A manual switch request overrides a previous manual switch request. Settting the value to none clears the forced/manual switch options configured on the interface\"",
"DEFVAL",
"{",
"none",
"}",
"::=",
"{",
"fsSynceIfEntry",
"14",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"none",
0
],
[
"forceSwitch",
1
],
[
"manualSwitch",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"When ForcedSwitch is enabled on an interface, it can override the currently selected synchronization source, provided the synchronization source is enabled and not locked out. The forced switch overrides the manual switch, and a subsequent forced switch pre-empts the previous forced switch.If the interface selected by the forced switch is disabled or locked out, the forced switch will be automatically rejected. A manual switch can be enabled on an interface provided the it is synce enabled, not locked out, not in signal fail condition, and has a QL better than DNU in QL-enabled mode. Furthermore, in QL-enabled mode, a manual switch can be performed only to a source which has the highest available QL. As such, these conditions have the effect that manual switching can only be used to override the assigned synchronization source priorities. A manual switch request overrides a previous manual switch request. Settting the value to none clears the forced/manual switch options configured on the interface"
],
null,
null,
null,
[
"DEFVAL",
"none"
]
]
}