1.3.6.1.4.1.30212.2.6600.3.1.2.1.32
Measured Transmitter Laser Bias, unit in 2uA
Identification
{1 3 6 1 4 1 30212 2 6600 3 1 2 1 32}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ONtel-6600, the row index oltSfpOltId is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.30212.2.6600.3.1.2.1.32.<oltSfpOltId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.30212.2.6600.3.1.2.1.32
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Parsed from ontel-6600.mib.txt · ontel · ONtel-6600
Source file: Download ontel-6600.mib.txt
Historical records
oltSfpTxBias OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured Transmitter Laser Bias, unit in 2uA"
::= { oltSfpEntry 32 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.1 | oltSfpOltId | 0 | 0 | Index of OLT |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.10 | oltSfpHaveInfo | 0 | 0 | SFP module has information eeprom |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.11 | oltSfpVendor | 0 | 0 | Vendor Name |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.12 | oltSfpPartNo | 0 | 0 | Part Number provided by vendor |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.13 | oltSfpRevision | 0 | 0 | Revision for Part Number |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.14 | oltSfpSerialNo | 0 | 0 | Serial Number provided by vendor |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.15 | oltSfpDateCode | 0 | 0 | Manufacturubg Date Code |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.16 | oltSfpXCVR | 0 | 0 | Type of Serial Tansceiver |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.17 | oltSfpConnector | 0 | 0 | Connector Type |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.18 | oltSfpEncoding | 0 | 0 | Connector Type |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.19 | oltSfpBitRate | 0 | 0 | Nominal bit rate, unit in 100Mbps |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.20 | oltSfpLinkLength | 0 | 0 | Link Length supported, unit in km |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.21 | oltSfpWaveLength | 0 | 0 | Laser Wavelength, unit in nm |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.22 | oltSfpHignMargin | 0 | 0 | Upper Bit Rate Margin, unit in % |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.23 | oltSfpLowMargin | 0 | 0 | Lower Bit Rate Margin, unit in % |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.24 | oltSfpCompat | 0 | 0 | Optical Compatibility |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.25 | oltSfpDiagnosis | 0 | 0 | Diagnosis Monitoring Type The various bit positions are: 8 received power measurement in average power 16 externally calib… |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.30 | oltSfpTemperature | 0 | 0 | Internally Measured Transceiver Temperature, unit in 1/256 degree C |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.31 | oltSfpVoltage | 0 | 0 | Internally Measured Supply Voltage, unit in 100uV |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.33 | oltSfpTxPower | 0 | 0 | Measured Received Optical Power, unit in 0.1uW |
| 1.3.6.1.4.1.30212.2.6600.3.1.2.1.34 | oltSfpRxPower | 0 | 0 | Measured Coupled Rx Ouput Power, unit in 0.1uW |