Description 1
Line 1 to Line 2 voltage
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3052.10.1.8.1.1.11
Line 1 to Line 2 voltage
Identification
{1 3 6 1 4 1 3052 10 1 8 1 1 11}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
acpmsVoltageL1L2Value OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line 1 to Line 2 voltage"
::= { acpmStatusEntry 11 }acpmsAvgCurrentValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average current, in amps. This is calculated using the formula
(register * CT ratio * 0.001). This could be either the average of
the phase currents, or the sum of the phase currents, depending on
device configuration."
::= { acpmStatusEntry 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Line 1 to Line 2 voltage
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Average current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the sum of the phase currents, depending on device configuration.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: acpmsVoltageL1L2Value
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"acpmsVoltageL1L2Value",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Line 1 to Line 2 voltage\"",
"::=",
"{",
"acpmStatusEntry",
"11",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Line 1 to Line 2 voltage"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SITEBOSS-550-STD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'TimeTicks', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'ASENTRIA-ROOT-MIB': ['asentria']}Related source files and packages:
Status in source: current.
Names: acpmsAvgCurrentValueStr
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"acpmsAvgCurrentValueStr",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Average current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the sum of the phase currents, depending on device configuration.\"",
"::=",
"{",
"acpmStatusEntry",
"11",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Average current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the sum of the phase currents, depending on device configuration."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SITEBOSS-550-STD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'TimeTicks', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'ASENTRIA-ROOT-MIB': ['asentria']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3052.10.1.8.1.1.52 | acpmsTAPMinStr, acpmsAPPhaseAValueStr | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.53 | acpmsTAPMaxStr, acpmsAPPhaseBValueStr | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.54 | acpmsTAPAvgStr, acpmsAPPhaseCValueStr | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.55 | acpmsAPPhaseAValueStr, acpmsTotalEnergyWh | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.56 | acpmsAPPhaseBValueStr, acpmsTotalEnergyVAR | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.57 | acpmsAPPhaseCValueStr, acpmsTotalEnergyVA | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.58 | acpmsTotalEnergyWh | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.59 | acpmsTotalEnergyVAR | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.60 | acpmsTotalEnergyVA | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.61 | acmpsAvgVoltageAlarmDatetime | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.62 | acmpsAvgCurrentAlarmDatetime | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.63 | acmpsFreqAlarmDatetime | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.64 | acmpsRealPowerAlarmDatetime | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.1.8.1.1.65 | acmpsPowerFactorAlarmDatetime | 0 | 0 |