Entry for AC power monitor device total power factor event config table.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3052.10.2.12.12.7.1
Entry for AC power monitor device total power factor event config table.
Identification
{1 3 6 1 4 1 3052 10 2 12 12 7 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
acpmTPFEntry OBJECT-TYPE
SYNTAX ACPMConfigTotalPowerFactor
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor device total power factor event config
table."
INDEX { acpmTPFIndex }
::= { acpmTotalPowerFactorTable 1 }acpmTPFEntry OBJECT-TYPE
SYNTAX ACPMConfigTotalPowerFactor
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor device total power factor event config
table."
INDEX { acpmTPFIndex }
::= { acpmTotalPowerFactorTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Entry for AC power monitor device total power factor event config table.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: acpmTPFEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"acpmTPFEntry",
"OBJECT-TYPE",
"SYNTAX",
"ACPMConfigTotalPowerFactor",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Entry for AC power monitor device total power factor event config table.\"",
"INDEX",
"{",
"acpmTPFIndex",
"}",
"::=",
"{",
"acpmTotalPowerFactorTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"ACPMConfigTotalPowerFactor"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Entry for AC power monitor device total power factor event config table."
],
null,
null,
[
"INDEX",
[
[
0,
"acpmTPFIndex"
]
]
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SITEBOSS-550-STD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'TimeTicks', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'ASENTRIA-ROOT-MIB': ['asentria']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SITEBOSS-550-STD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'TimeTicks', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'ASENTRIA-ROOT-MIB': ['asentria']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.1 | acpmTPFIndex | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.2 | acpmTPFEnable | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.3 | acpmTPFDeadband | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.4 | acpmTPFNormalActions | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.5 | acpmTPFNormalTrapNum | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.6 | acpmTPFNormalClass | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.7 | acpmTPFLowValue | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.8 | acpmTPFLowActions | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.9 | acpmTPFLowTrapNum | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.10 | acpmTPFLowClass | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.11 | acpmTPFVLowValue | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.12 | acpmTPFVLowActions | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.13 | acpmTPFVLowTrapNum | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.14 | acpmTPFVLowClass | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.15 | acpmTPFSysrepEnable | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.16 | acpmTPFSysrepThreshold | 0 | 0 | |
| 1.3.6.1.4.1.3052.10.2.12.12.7.1.17 | acpmTPFSysrepLimit | 0 | 0 |