Trap number for low voltage event.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3052.17.2.12.14.5.1.17
Trap number for low voltage event.
Identification
{1 3 6 1 4 1 3052 17 2 12 14 5 1 17}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In SITEBOSS-450-STD-MIB, the row index bmVoltageIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.3052.17.2.12.14.5.1.17.<bmVoltageIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3052.17.2.12.14.5.1.17
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
bmVoltageLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for low voltage event."
::= { bmVoltageEntry 17 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Trap number for low voltage event.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: bmVoltageLowTrapNum
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"bmVoltageLowTrapNum",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Trap number for low voltage event.\"",
"::=",
"{",
"bmVoltageEntry",
"17",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Trap number for low voltage event."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SITEBOSS-450-STD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'TimeTicks', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'ASENTRIA-ROOT-MIB': ['asentria']}Related source files and packages:
Registration