Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.31034.12.1.1.2.2.1.1.3
Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.
Identification
{1 3 6 1 4 1 31034 12 1 1 2 2 1 1 3}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In SCHLEIFENBAUER-DATABUS-MIB, the row index sdbDevIdIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.31034.12.1.1.2.2.1.1.3.<sdbDevIdIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.31034.12.1.1.2.2.1.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
sdbDevCfOutletsSwitched OBJECT-TYPE
SYNTAX Integer32 (0..54)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of switched outlets.
If outlet numbering is non-contiguous its the highest outlet number."
::= { sdbDevCfEntry 3 }sdbDevCfOutletsSwitched OBJECT-TYPE
SYNTAX Integer32 (0..48)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of switched outlets.
If outlet numbering is non-contiguous its the highest outlet number."
::= { sdbDevCfEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sdbDevCfOutletsSwitched
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sdbDevCfOutletsSwitched",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"54",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.\"",
"::=",
"{",
"sdbDevCfEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
54
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SCHLEIFENBAUER-DATABUS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP', 'MODULE-COMPLIANCE'], 'SCHLEIFENBAUER-SMI': ['schleifenbauerMgmt']}Related source files and packages:
Same file in Observium Community.
Status in source: current.
Names: sdbDevCfOutletsSwitched
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sdbDevCfOutletsSwitched",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"48",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.\"",
"::=",
"{",
"sdbDevCfEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
48
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Netdisco archive.
Module: SCHLEIFENBAUER-DATABUS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP', 'MODULE-COMPLIANCE'], 'SCHLEIFENBAUER-SMI': ['schleifenbauerMgmt']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.1 | sdbDevCfPhases | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.2 | sdbDevCfOutletsTotal | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.4 | sdbDevCfOutletsMetered | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.5 | sdbDevCfSensors | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.6 | sdbDevCfMaximumLoad | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.7 | sdbDevCfBranches | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.8 | sdbDevCfNeutral | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.9 | sdbDevCfTempSensors | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.10 | sdbDevCfTotals | 0 | 0 |