OID reference

sdbDevInActualVoltage

1.3.6.1.4.1.31034.12.1.1.2.6.1.1.7

Description

The actual voltage.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.31034.12.1.1.2.6.1.1 (sdbDevInEntry)
Node code
7
Node name
sdbDevInActualVoltage
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.7
URN notation
urn:oid:1.3.6.1.4.1.31034.12.1.1.2.6.1.1.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 31034 12 1 1 2 6 1 1 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) schleifenbauer(31034) schleifenbauerMgmt(12) schleifenbauerDatabusMIB(1) sdbMIBObjects(1) sdbDevice(2) sdbDevInput(6) sdbDevInTable(1) sdbDevInEntry(1) sdbDevInActualVoltage(7)}
OID-IRI notation
  • /1/3/6/1/4/1/31034/12/1/1/2/6/1/1/7
  • /ISO/Identified-Organization/6/1/4/1/31034/12/1/1/2/6/1/1/7
  • /ISO/3/6/1/4/1/31034/12/1/1/2/6/1/1/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/identified-organization/dod/internet/private/enterprise/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/identified-organization/dod/internet/private/enterprises/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/identified-organization/dod/internet/private/enterprises/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/identified-organization/dod/internet/private/vendor-objects/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/identified-organization/dod/internet/private/vendor-objects/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/enterprise/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/enterprise/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/enterprises/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/enterprises/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/ldap-enterprise/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/ldap-enterprise/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/vendor-objects/31034/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • /iso/org/dod/internet/private/vendor-objects/schleifenbauer/schleifenbauerMgmt/schleifenbauerDatabusMIB/sdbMIBObjects/sdbDevice/sdbDevInput/sdbDevInTable/sdbDevInEntry/sdbDevInActualVoltage
  • Additional combinations skipped.

SNMP properties

Value type
CentiVolt, DeciVolt
Units
V
Maximum access defined by MIB
read-only
Status in MIB
current

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
CentiVolt
Units
V
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 2 — Netdisco MIB archive copies

Value type
DeciVolt
Units
V
Maximum access defined by MIB
read-only
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

sdbDevInActualVoltage · current

sdbDevInActualVoltage OBJECT-TYPE
    SYNTAX      CentiVolt
    UNITS       "V"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The actual voltage."
    ::= { sdbDevInEntry 7 }

sdbDevInActualVoltage · current

sdbDevInActualVoltage OBJECT-TYPE
    SYNTAX      DeciVolt
    UNITS       "V"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The actual voltage."
    ::= { sdbDevInEntry 7 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The actual voltage.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies2 records · 2 sources

Description 1

sdbDevInActualVoltage · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: sdbDevInActualVoltage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sdbDevInActualVoltage",
    "OBJECT-TYPE",
    "SYNTAX",
    "CentiVolt",
    "UNITS",
    [
      "literal",
      "225622"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The actual voltage.\"",
    "::=",
    "{",
    "sdbDevInEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "CentiVolt"
    ],
    [
      "UNITS",
      "V"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The actual voltage."
    ],
    null,
    null,
    null,
    null
  ]
}
sdbDevInActualVoltage · currentNetdisco MIB archive copies1 source

Status in source: current.

Names: sdbDevInActualVoltage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sdbDevInActualVoltage",
    "OBJECT-TYPE",
    "SYNTAX",
    "DeciVolt",
    "UNITS",
    [
      "literal",
      "225622"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The actual voltage.\"",
    "::=",
    "{",
    "sdbDevInEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "DeciVolt"
    ],
    [
      "UNITS",
      "V"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The actual voltage."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.31034)

Alain Schuermans

Siblings (13)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.1 sdbDevInIndex00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.2 sdbDevInKWhTotal00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.3 sdbDevInKWhSubtotal00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.4 sdbDevInPowerFactor00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.5 sdbDevInActualCurrent00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.6 sdbDevInPeakCurrent00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.8 sdbDevInMinVoltage00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.9 sdbDevInPowerVoltAmpere00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.10 sdbDevInPowerWatt00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.11 sdbDevInMaxAmps00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.12 sdbDevInCTRatio00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.13 sdbDevInName00
1.3.6.1.4.1.31034.12.1.1.2.6.1.1.14 sdbDevInZeroKWhSubtotal00