Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.31034.12.1.1.2.7.2.1.8
Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.
Identification
{1 3 6 1 4 1 31034 12 1 1 2 7 2 1 8}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
sdbDevOutMtMaxAmps OBJECT-TYPE
SYNTAX CentiAmpere
UNITS "A"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum current per outlet.
Should last at least sdbDevStPeakDuration ms before triggering an
alert."
::= { sdbDevOutMtEntry 8 }sdbDevOutMtMaxAmps OBJECT-TYPE
SYNTAX DeciAmpere
UNITS "A"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum current per outlet.
Should last at least sdbDevStPeakDuration ms before triggering an
alert."
::= { sdbDevOutMtEntry 8 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sdbDevOutMtMaxAmps
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sdbDevOutMtMaxAmps",
"OBJECT-TYPE",
"SYNTAX",
"CentiAmpere",
"UNITS",
[
"literal",
"224122"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.\"",
"::=",
"{",
"sdbDevOutMtEntry",
"8",
"}"
],
"syntax_tree": [
[
"row",
"CentiAmpere"
],
[
"UNITS",
"A"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SCHLEIFENBAUER-DATABUS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP', 'MODULE-COMPLIANCE'], 'SCHLEIFENBAUER-SMI': ['schleifenbauerMgmt']}Related source files and packages:
Same file in Observium Community.
Status in source: current.
Names: sdbDevOutMtMaxAmps
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sdbDevOutMtMaxAmps",
"OBJECT-TYPE",
"SYNTAX",
"DeciAmpere",
"UNITS",
[
"literal",
"224122"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.\"",
"::=",
"{",
"sdbDevOutMtEntry",
"8",
"}"
],
"syntax_tree": [
[
"row",
"DeciAmpere"
],
[
"UNITS",
"A"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Netdisco archive.
Module: SCHLEIFENBAUER-DATABUS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP', 'MODULE-COMPLIANCE'], 'SCHLEIFENBAUER-SMI': ['schleifenbauerMgmt']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.1 | sdbDevOutMtIndex | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2 | sdbDevOutMtKWhTotal | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.3 | sdbDevOutMtKWhSubtotal | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.4 | sdbDevOutMtPowerFactor | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.5 | sdbDevOutMtActualCurrent | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.6 | sdbDevOutMtPeakCurrent | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.7 | sdbDevOutMtActualVoltage | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.9 | sdbDevOutMtCTRatio | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.10 | sdbDevOutMtPowerVoltAmpere | 0 | 0 | |
| 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.11 | sdbDevOutMtPowerWatt | 0 | 0 |