OID reference

ignis

1.3.6.1.4.1.31225.1.1

Description

PPM IGNIS (ViaLiteHD) MIB This MIB defines the data objects available for use with the ViaLiteHD Web & SNMP Controller module. This MIB is incompatible with the ViaLite Classic MIB. This MIB (as of version 1.2) must be loaded with the PPM-ORG-MIB. This MIB includes OIDs originally defined in the PPM-TRAPS-MIB, and suc…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.31225.1 (vialiteProducts)
Node code
1
Node name
ignis
Numeric OID
1.3.6.1.4.1.31225.1.1
URN notation
urn:oid:1.3.6.1.4.1.31225.1.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 31225 1 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppm(31225) vialiteProducts(1) ignis(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppm(31225) vialiteProducts(1) ignis(1)}
OID-IRI notation
  • /1/3/6/1/4/1/31225/1/1
  • /ISO/Identified-Organization/6/1/4/1/31225/1/1
  • /ISO/3/6/1/4/1/31225/1/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/31225/vialiteProducts/ignis
  • /iso/identified-organization/dod/internet/private/enterprise/ppm/vialiteProducts/ignis
  • /iso/identified-organization/dod/internet/private/enterprises/31225/vialiteProducts/ignis
  • /iso/identified-organization/dod/internet/private/enterprises/ppm/vialiteProducts/ignis
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/31225/vialiteProducts/ignis
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ppm/vialiteProducts/ignis
  • /iso/identified-organization/dod/internet/private/vendor-objects/31225/vialiteProducts/ignis
  • /iso/identified-organization/dod/internet/private/vendor-objects/ppm/vialiteProducts/ignis
  • /iso/org/dod/internet/private/enterprise/31225/vialiteProducts/ignis
  • /iso/org/dod/internet/private/enterprise/ppm/vialiteProducts/ignis
  • /iso/org/dod/internet/private/enterprises/31225/vialiteProducts/ignis
  • /iso/org/dod/internet/private/enterprises/ppm/vialiteProducts/ignis
  • /iso/org/dod/internet/private/ldap-enterprise/31225/vialiteProducts/ignis
  • /iso/org/dod/internet/private/ldap-enterprise/ppm/vialiteProducts/ignis
  • /iso/org/dod/internet/private/vendor-objects/31225/vialiteProducts/ignis
  • /iso/org/dod/internet/private/vendor-objects/ppm/vialiteProducts/ignis
  • Additional combinations skipped.

The displayed source records contain one distinct definition. Compare its source records.

ignis    MODULE-IDENTITY
		LAST-UPDATED "202207121300Z"
		ORGANIZATION
				"Pulse Power & Measurement Ltd."
		CONTACT-INFO
				"
				Postal:     65 Shrivenham Hundred Business Park
				Watchfield
				Swindon, Wiltshire. SN6 8TY, UK
				Telephone:  +44 (0)1793 784389
				E-Mail:     sales@ppm.co.uk  "
		DESCRIPTION
				"PPM IGNIS (ViaLiteHD) MIB

				This MIB defines the data objects available for use with the
				ViaLiteHD Web & SNMP Controller module.

				This MIB is incompatible with the ViaLite Classic MIB.

				This MIB (as of version 1.2) must be loaded with the PPM-ORG-MIB.
				This MIB includes OIDs originally defined in the PPM-TRAPS-MIB, 
				and such the PPM-TRAPS-MIB should be replaced with the PPM-IGNIS-V1TRAPS-MIB.
				
				Pulse Power & Measurement Ltd. reserves the right to make changes in specifications 
				and all other information contained in this document without prior notice.
				
				Pulse Power & Measurement Ltd. grants vendors, end-users, and other interested parties 
				a non-exclusive license to use this specification in connection with the management of
				Pulse Power & Measurement products."
		
		
		REVISION
				"202207221300Z"
		DESCRIPTION
				"1.34 - Add support for 6GHz MilAero products
						Correct AGC mode enumeration
						Add SNMP controller P/N query"
		REVISION
				"202204121300Z"
		DESCRIPTION
				"1.33 - Added support for PROC rack card."
		REVISION
				"202202091300Z"
		DESCRIPTION
				"1.32 - Added ODE-A4 enclosure product type."
		REVISION
				"202109231300Z"
		DESCRIPTION
				"1.31 - Added LED off status to mcpLEDs."
		REVISION
				"202007221300Z"
		DESCRIPTION
				"1.3 - Add enumeration for the ODE Mini Enclosure (fitted with Embedded Site Controller). Move Trap Sink and FTP update MIB sections to PPM-ORG-MIB as these may be used in other products."
		REVISION
				"201907161300Z"
		DESCRIPTION
				"1.29 - Add sysVoltageAlarm and sysTempAlarm OIDs to monitor the current state of the HRC-3 temperature and voltage alarms (HRC-3 only)."
		REVISION
				"201905211300Z"
		DESCRIPTION
				"1.28 - Correct modSWAlarmBitMap mapping."
		REVISION
				"201903011300Z"
		DESCRIPTION
				"1.27 - Remove read-write support for Tx TEC enable. TEC should be permanently enabled."	
		REVISION
				"201807051300Z"
		DESCRIPTION
				"1.26 - Add support for the ViaLiteHD 1U GPS Splitter rack"	
		REVISION
				"201710111300Z"
		DESCRIPTION
				"1.25 - Add the HRC-3 specific OIDS
						Add the Trap history table OIDs to this MIB
						Update the OID definitions & clarify the explanations"				
				
		REVISION
				"201701101300Z"
		DESCRIPTION
				"1.2 - Update to reference new PPM GENERIC MIB structure."
		REVISION
				"201611301300Z"
		DESCRIPTION
				"1.15 - Update for standards compliance, and to improve MIB useability."
		REVISION
				"201602231300Z"
		DESCRIPTION
				"1.14 - Fix some typos."
		REVISION
				"201601311200Z"
		DESCRIPTION
				"1.13 - Add description"
		REVISION
				"201507151200Z"
		DESCRIPTION
				"1.12 - Add support for Tx TEC monitor & control OIDs"
		REVISION
				"201504281200Z"
		DESCRIPTION
				"1.11 - Change OID 351 description"
		REVISION
				"201504141200Z"
		DESCRIPTION
				"1.10 - Add modSwitchModeSetting"
		REVISION
				"201408041200Z"
		DESCRIPTION
				"1.09 - General fixes. Serial alarm OIDs removed, consolidated into one OID."
		REVISION
				"201407231200Z"
		DESCRIPTION
				"1.08 - Added: 	New configuration parameter for TX LNB alarm severity
								Support for DC switched splitter module
								New serial parameters
						Changed: Serial Configuration parameter OIDs"
		REVISION
				"201309091200Z"
		DESCRIPTION
				"1.07 - Add support for SATCOM6 device."
		REVISION
				"201303111200Z"
		DESCRIPTION
				"1.06 - Adjust ethernet card parameters"
		REVISION
				"201207011200Z"
		DESCRIPTION
				"1.05 - Add support for 1RU device."
		REVISION
				"201010121200Z"
		DESCRIPTION
				"1.03 - LNB related enumerations fixed."
		REVISION
				"201006101200Z"
		DESCRIPTION
				"1.02 - Amplifier support added."
		REVISION
				"200912091200Z"
		DESCRIPTION
				"1.01 - First released version."
	::=  { vialiteProducts 1 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

PPM IGNIS (ViaLiteHD) MIB This MIB defines the data objects available for use with the ViaLiteHD Web & SNMP Controller module. This MIB is incompatible with the ViaLite Classic MIB. This MIB (as of version 1.2) must be loaded with the PPM-ORG-MIB. This MIB includes OIDs originally defined in the PPM-TRAPS-MIB, and such the PPM-TRAPS-MIB should be replaced with the PPM-IGNIS-V1TRAPS-MIB. Pulse Power & Measurement Ltd. reserves the right to make changes in specifications and all other information contained in this document without prior notice. Pulse Power & Measurement Ltd. grants vendors, end-users, and other interested parties a non-exclusive license to use this specification in connection with the management of Pulse Power & Measurement products.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

ignis · unspecifiedMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: unspecified.

Names: ignis

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "ignis",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230323230373132313330305a22"
    ],
    "ORGANIZATION",
    "\"Pulse Power & Measurement Ltd.\"",
    "CONTACT-INFO",
    "\" Postal: 65 Shrivenham Hundred Business Park Watchfield Swindon, Wiltshire. SN6 8TY, UK Telephone: +44 (0)1793 784389 E-Mail: sales@ppm.co.uk \"",
    "DESCRIPTION",
    "\"PPM IGNIS (ViaLiteHD) MIB This MIB defines the data objects available for use with the ViaLiteHD Web & SNMP Controller module. This MIB is incompatible with the ViaLite Classic MIB. This MIB (as of version 1.2) must be loaded with the PPM-ORG-MIB. This MIB includes OIDs originally defined in the PPM-TRAPS-MIB, and such the PPM-TRAPS-MIB should be replaced with the PPM-IGNIS-V1TRAPS-MIB. Pulse Power & Measurement Ltd. reserves the right to make changes in specifications and all other information contained in this document without prior notice. Pulse Power & Measurement Ltd. grants vendors, end-users, and other interested parties a non-exclusive license to use this specification in connection with the management of Pulse Power & Measurement products.\"",
    "REVISION",
    [
      "literal",
      "223230323230373232313330305a22"
    ],
    "DESCRIPTION",
    "\"1.34 - Add support for 6GHz MilAero products Correct AGC mode enumeration Add SNMP controller P/N query\"",
    "REVISION",
    [
      "literal",
      "223230323230343132313330305a22"
    ],
    "DESCRIPTION",
    "\"1.33 - Added support for PROC rack card.\"",
    "REVISION",
    [
      "literal",
      "223230323230323039313330305a22"
    ],
    "DESCRIPTION",
    "\"1.32 - Added ODE-A4 enclosure product type.\"",
    "REVISION",
    [
      "literal",
      "223230323130393233313330305a22"
    ],
    "DESCRIPTION",
    "\"1.31 - Added LED off status to mcpLEDs.\"",
    "REVISION",
    [
      "literal",
      "223230323030373232313330305a22"
    ],
    "DESCRIPTION",
    "\"1.3 - Add enumeration for the ODE Mini Enclosure (fitted with Embedded Site Controller). Move Trap Sink and FTP update MIB sections to PPM-ORG-MIB as these may be used in other products.\"",
    "REVISION",
    [
      "literal",
      "223230313930373136313330305a22"
    ],
    "DESCRIPTION",
    "\"1.29 - Add sysVoltageAlarm and sysTempAlarm OIDs to monitor the current state of the HRC-3 temperature and voltage alarms (HRC-3 only).\"",
    "REVISION",
    [
      "literal",
      "223230313930353231313330305a22"
    ],
    "DESCRIPTION",
    "\"1.28 - Correct modSWAlarmBitMap mapping.\"",
    "REVISION",
    [
      "literal",
      "223230313930333031313330305a22"
    ],
    "DESCRIPTION",
    "\"1.27 - Remove read-write support for Tx TEC enable. TEC should be permanently enabled.\"",
    "REVISION",
    [
      "literal",
      "223230313830373035313330305a22"
    ],
    "DESCRIPTION",
    "\"1.26 - Add support for the ViaLiteHD 1U GPS Splitter rack\"",
    "REVISION",
    [
      "literal",
      "223230313731303131313330305a22"
    ],
    "DESCRIPTION",
    "\"1.25 - Add the HRC-3 specific OIDS Add the Trap history table OIDs to this MIB Update the OID definitions & clarify the explanations\"",
    "REVISION",
    [
      "literal",
      "223230313730313130313330305a22"
    ],
    "DESCRIPTION",
    "\"1.2 - Update to reference new PPM GENERIC MIB structure.\"",
    "REVISION",
    [
      "literal",
      "223230313631313330313330305a22"
    ],
    "DESCRIPTION",
    "\"1.15 - Update for standards compliance, and to improve MIB useability.\"",
    "REVISION",
    [
      "literal",
      "223230313630323233313330305a22"
    ],
    "DESCRIPTION",
    "\"1.14 - Fix some typos.\"",
    "REVISION",
    [
      "literal",
      "223230313630313331313230305a22"
    ],
    "DESCRIPTION",
    "\"1.13 - Add description\"",
    "REVISION",
    [
      "literal",
      "223230313530373135313230305a22"
    ],
    "DESCRIPTION",
    "\"1.12 - Add support for Tx TEC monitor & control OIDs\"",
    "REVISION",
    [
      "literal",
      "223230313530343238313230305a22"
    ],
    "DESCRIPTION",
    "\"1.11 - Change OID 351 description\"",
    "REVISION",
    [
      "literal",
      "223230313530343134313230305a22"
    ],
    "DESCRIPTION",
    "\"1.10 - Add modSwitchModeSetting\"",
    "REVISION",
    [
      "literal",
      "223230313430383034313230305a22"
    ],
    "DESCRIPTION",
    "\"1.09 - General fixes. Serial alarm OIDs removed, consolidated into one OID.\"",
    "REVISION",
    [
      "literal",
      "223230313430373233313230305a22"
    ],
    "DESCRIPTION",
    "\"1.08 - Added: New configuration parameter for TX LNB alarm severity Support for DC switched splitter module New serial parameters Changed: Serial Configuration parameter OIDs\"",
    "REVISION",
    [
      "literal",
      "223230313330393039313230305a22"
    ],
    "DESCRIPTION",
    "\"1.07 - Add support for SATCOM6 device.\"",
    "REVISION",
    [
      "literal",
      "223230313330333131313230305a22"
    ],
    "DESCRIPTION",
    "\"1.06 - Adjust ethernet card parameters\"",
    "REVISION",
    [
      "literal",
      "223230313230373031313230305a22"
    ],
    "DESCRIPTION",
    "\"1.05 - Add support for 1RU device.\"",
    "REVISION",
    [
      "literal",
      "223230313031303132313230305a22"
    ],
    "DESCRIPTION",
    "\"1.03 - LNB related enumerations fixed.\"",
    "REVISION",
    [
      "literal",
      "223230313030363130313230305a22"
    ],
    "DESCRIPTION",
    "\"1.02 - Amplifier support added.\"",
    "REVISION",
    [
      "literal",
      "223230303931323039313230305a22"
    ],
    "DESCRIPTION",
    "\"1.01 - First released version.\"",
    "::=",
    "{",
    "vialiteProducts",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "202207121300Z"
    ],
    [
      "ORGANIZATION",
      "Pulse Power & Measurement Ltd."
    ],
    [
      "CONTACT-INFO",
      "Postal: 65 Shrivenham Hundred Business Park Watchfield Swindon, Wiltshire. SN6 8TY, UK Telephone: +44 (0)1793 784389 E-Mail: sales@ppm.co.uk"
    ],
    [
      "DESCRIPTION",
      "PPM IGNIS (ViaLiteHD) MIB This MIB defines the data objects available for use with the ViaLiteHD Web & SNMP Controller module. This MIB is incompatible with the ViaLite Classic MIB. This MIB (as of version 1.2) must be loaded with the PPM-ORG-MIB. This MIB includes OIDs originally defined in the PPM-TRAPS-MIB, and such the PPM-TRAPS-MIB should be replaced with the PPM-IGNIS-V1TRAPS-MIB. Pulse Power & Measurement Ltd. reserves the right to make changes in specifications and all other information contained in this document without prior notice. Pulse Power & Measurement Ltd. grants vendors, end-users, and other interested parties a non-exclusive license to use this specification in connection with the management of Pulse Power & Measurement products."
    ],
    [
      "Revisions",
      [
        [
          "202207221300Z",
          [
            "DESCRIPTION",
            "1.34 - Add support for 6GHz MilAero products Correct AGC mode enumeration Add SNMP controller P/N query"
          ]
        ],
        [
          "202204121300Z",
          [
            "DESCRIPTION",
            "1.33 - Added support for PROC rack card."
          ]
        ],
        [
          "202202091300Z",
          [
            "DESCRIPTION",
            "1.32 - Added ODE-A4 enclosure product type."
          ]
        ],
        [
          "202109231300Z",
          [
            "DESCRIPTION",
            "1.31 - Added LED off status to mcpLEDs."
          ]
        ],
        [
          "202007221300Z",
          [
            "DESCRIPTION",
            "1.3 - Add enumeration for the ODE Mini Enclosure (fitted with Embedded Site Controller). Move Trap Sink and FTP update MIB sections to PPM-ORG-MIB as these may be used in other products."
          ]
        ],
        [
          "201907161300Z",
          [
            "DESCRIPTION",
            "1.29 - Add sysVoltageAlarm and sysTempAlarm OIDs to monitor the current state of the HRC-3 temperature and voltage alarms (HRC-3 only)."
          ]
        ],
        [
          "201905211300Z",
          [
            "DESCRIPTION",
            "1.28 - Correct modSWAlarmBitMap mapping."
          ]
        ],
        [
          "201903011300Z",
          [
            "DESCRIPTION",
            "1.27 - Remove read-write support for Tx TEC enable. TEC should be permanently enabled."
          ]
        ],
        [
          "201807051300Z",
          [
            "DESCRIPTION",
            "1.26 - Add support for the ViaLiteHD 1U GPS Splitter rack"
          ]
        ],
        [
          "201710111300Z",
          [
            "DESCRIPTION",
            "1.25 - Add the HRC-3 specific OIDS Add the Trap history table OIDs to this MIB Update the OID definitions & clarify the explanations"
          ]
        ],
        [
          "201701101300Z",
          [
            "DESCRIPTION",
            "1.2 - Update to reference new PPM GENERIC MIB structure."
          ]
        ],
        [
          "201611301300Z",
          [
            "DESCRIPTION",
            "1.15 - Update for standards compliance, and to improve MIB useability."
          ]
        ],
        [
          "201602231300Z",
          [
            "DESCRIPTION",
            "1.14 - Fix some typos."
          ]
        ],
        [
          "201601311200Z",
          [
            "DESCRIPTION",
            "1.13 - Add description"
          ]
        ],
        [
          "201507151200Z",
          [
            "DESCRIPTION",
            "1.12 - Add support for Tx TEC monitor & control OIDs"
          ]
        ],
        [
          "201504281200Z",
          [
            "DESCRIPTION",
            "1.11 - Change OID 351 description"
          ]
        ],
        [
          "201504141200Z",
          [
            "DESCRIPTION",
            "1.10 - Add modSwitchModeSetting"
          ]
        ],
        [
          "201408041200Z",
          [
            "DESCRIPTION",
            "1.09 - General fixes. Serial alarm OIDs removed, consolidated into one OID."
          ]
        ],
        [
          "201407231200Z",
          [
            "DESCRIPTION",
            "1.08 - Added: New configuration parameter for TX LNB alarm severity Support for DC switched splitter module New serial parameters Changed: Serial Configuration parameter OIDs"
          ]
        ],
        [
          "201309091200Z",
          [
            "DESCRIPTION",
            "1.07 - Add support for SATCOM6 device."
          ]
        ],
        [
          "201303111200Z",
          [
            "DESCRIPTION",
            "1.06 - Adjust ethernet card parameters"
          ]
        ],
        [
          "201207011200Z",
          [
            "DESCRIPTION",
            "1.05 - Add support for 1RU device."
          ]
        ],
        [
          "201010121200Z",
          [
            "DESCRIPTION",
            "1.03 - LNB related enumerations fixed."
          ]
        ],
        [
          "201006101200Z",
          [
            "DESCRIPTION",
            "1.02 - Amplifier support added."
          ]
        ],
        [
          "200912091200Z",
          [
            "DESCRIPTION",
            "1.01 - First released version."
          ]
        ]
      ]
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.31225)

Jacek Batkowski

Direct children (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.31225.1.1.1 ignisSystem2323
1.3.6.1.4.1.31225.1.1.4 ignisSlots1215