Variable status is ok.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.31770.2.3.0.7
Variable status is ok.
Identification
{1 3 6 1 4 1 31770 2 3 0 7}
The displayed source records contain one distinct definition. Compare its source records.
blueNet2VariableStatusOkTrap NOTIFICATION-TYPE
OBJECTS {
blueNet2VariableDataGuid,
blueNet2VariableDataStatus,
blueNet2VariableDataValue,
blueNet2VariableAlarm
}
STATUS current
DESCRIPTION "Variable status is ok."
--
-- #CATEGORY "Threshold Events."
-- #TYPE "Variable status is ok."
-- #SUMMARY "Guid %x variable value %i is ok (%i), %s."
-- #ARGUMENTS {0,1,2,3}
-- #SEVERITY INFORMATIONAL
-- #STATE OPERATIONAL
--
::= { blueNet2TrapPrefix 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Variable status is ok.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: blueNet2VariableStatusOkTrap
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"blueNet2VariableStatusOkTrap",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"blueNet2VariableDataGuid",
",",
"blueNet2VariableDataStatus",
",",
"blueNet2VariableDataValue",
",",
"blueNet2VariableAlarm",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Variable status is ok.\"",
"::=",
"{",
"blueNet2TrapPrefix",
"7",
"}"
],
"syntax_tree": [
[
"Objects",
[
"blueNet2VariableDataGuid",
"blueNet2VariableDataStatus",
"blueNet2VariableDataValue",
"blueNet2VariableAlarm"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Variable status is ok."
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: BACHMANN-BLUENET2-MIB
See published definition above
{'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-MIB': ['sysObjectID'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'BACHMANN-SMI-MIB': ['bachmann']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.31770.2.3.0.1 | blueNet2PduStatusOkTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.2 | blueNet2PduStatusWarningTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.3 | blueNet2PduStatusAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.4 | blueNet2SensorStatusOkTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.5 | blueNet2SensorStatusWarningTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.6 | blueNet2SensorStatusAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.8 | blueNet2VariableLowerWarningTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.9 | blueNet2VariableUpperWarningTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.10 | blueNet2VariableLowerAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.11 | blueNet2VariableUpperAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.12 | blueNet2RCMSelftestResultTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.98 | blueNet2ReconfigAgentTrap | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.3.0.99 | blueNet2ShutdownAgentTrap | 0 | 0 |