A list of UPS table entries. The number of entries is given by the value of upsParallelSysUpsTableize.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.318.1.1.1.14.17
A list of UPS table entries. The number of entries is given by the value of upsParallelSysUpsTableize.
Identification
{1 3 6 1 4 1 318 1 1 1 14 17}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
upsParallelSysUpsTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsParallelSysUpsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of UPS table entries. The number of entries
is given by the value of upsParallelSysUpsTableize."
::= { upsParallelSystem 17 }upsParallelSysUpsTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsParallelSysUpsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of UPS table entries. The number of entries
is given by the value of upsParallelSysUpsTableize."
::= { upsParallelSystem 17 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A list of UPS table entries. The number of entries is given by the value of upsParallelSysUpsTableize.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: upsParallelSysUpsTable
Vendor MIB copy from the LibreNMS archive.
Module: PowerNet-MIB
See published definition above
· Download PowerNet-MIBRelated source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: PowerNet-MIB
See published definition above
· Download PowerNet-MIBRegistration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.1.14.17.1 | upsParallelSysUpsEntry | 5 | 5 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.1.14.1 | upsParallelSysLocalAddress | 1 | 1 | Defines the UPS ID number in the parallel system. |
| 1.3.6.1.4.1.318.1.1.1.14.2 | upsParallelSysRemoteAddress | 1 | 1 | Defines the total number of UPSs in parallel. |
| 1.3.6.1.4.1.318.1.1.1.14.3 | upsParallelSysRedundancy | 1 | 1 | The redundancy warning level for paralleled UPS nplus0 (1) indicates that there are no redundant units. nplus1 (2) indicates that… |
| 1.3.6.1.4.1.318.1.1.1.14.4 | upsParallelInputMaximumCurrent | 0 | 0 | Maximum input RMS current of the parallel system measured in Amperes. |
| 1.3.6.1.4.1.318.1.1.1.14.5 | upsParallelTotalOutputPower | 0 | 0 | The Total Ouptut power of UPS in KW when UPS are configured in parallel or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.6 | upsParallelTotalOutputApparentPower | 0 | 0 | The Total Ouptut Apparent power of UPS in kVA when UPS are configured in parallel or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.7 | upsParallelInputPhaseTable | 1 | 11 | A list of input table entries. |
| 1.3.6.1.4.1.318.1.1.1.14.8 | upsParallelOutputPhaseTable | 1 | 7 | A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases. |
| 1.3.6.1.4.1.318.1.1.1.14.9 | upsParallelOutputApparentPowerTable | 1 | 3 | A list of output table entries. The number of entries is given by the value of upsOutputNumPhases. |
| 1.3.6.1.4.1.318.1.1.1.14.10 | upsParallelDiagSubSysBreakerTable | 1 | 5 | Allows for diagnostics of parallel Circuit Breakers. |
| 1.3.6.1.4.1.318.1.1.1.14.11 | upsParallelOutputTotalPercentLoad | 0 | 0 | The percentage of the UPS total load capacity in kVA or -1 if it's unsupported by this UPS. |
| 1.3.6.1.4.1.318.1.1.1.14.12 | upsParallelOutputActivePowerTable | 1 | 3 | A list of output table entries. The number of entries is given by the value of upsParallelSysRemoteAddress. |
| 1.3.6.1.4.1.318.1.1.1.14.13 | upsParallelSysSwitchGearInstallationLoadPct | 0 | 0 | The actual output load expressed as a percentage of the rating of the Parallel UPS system. |
| 1.3.6.1.4.1.318.1.1.1.14.14 | upsParallelSysRedundancyStatus | 0 | 0 | Displays the number of backup or redundant UPSs set up on the parallel system. nplus0 (1) no redundant units. nplus1 (2) one redu… |
| 1.3.6.1.4.1.318.1.1.1.14.15 | upsParallelSysName | 0 | 0 | An ID string for the group of UPS units in the same parallel system. Some products do not allow write operations for this OID. |
| 1.3.6.1.4.1.318.1.1.1.14.16 | upsParallelSysUpsTableSize | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.14.18 | upsParallelNumOfUpsPoweringLoad | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.14.19 | upsParallelMinNumOfRequiredUps | 0 | 0 |