The input total active power(sum of all three phases) of the UPS system in kW. If not supported, return -1
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.318.1.1.1.3.2.12
The input total active power(sum of all three phases) of the UPS system in kW. If not supported, return -1
Identification
{1 3 6 1 4 1 318 1 1 1 3 2 12}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.318.1.1.1.3.2.12.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
upsAdvInputTotalActivePower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input total active power(sum of all three phases) of the UPS system in kW.
If not supported, return -1"
::= { upsAdvInput 12 }upsAdvInputTotalActivePower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input total active power(sum of all three phases) of the UPS system in kW.
If not supported, return -1"
::= { upsAdvInput 12 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The input total active power(sum of all three phases) of the UPS system in kW. If not supported, return -1
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: upsAdvInputTotalActivePower
Vendor MIB copy from the LibreNMS archive.
Module: PowerNet-MIB
See published definition above
· Download PowerNet-MIBRelated source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: PowerNet-MIB
See published definition above
· Download PowerNet-MIBRegistration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.1.3.2.1 | upsAdvInputLineVoltage | 1 | 1 | The current utility line voltage in VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.2.2 | upsAdvInputMaxLineVoltage | 1 | 1 | The maximum utility line voltage in VAC over the previous 1 minute period. |
| 1.3.6.1.4.1.318.1.1.1.3.2.3 | upsAdvInputMinLineVoltage | 1 | 1 | The minimum utility line voltage in VAC over the previous 1 minute period. |
| 1.3.6.1.4.1.318.1.1.1.3.2.4 | upsAdvInputFrequency | 1 | 1 | The current input frequency to the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.3.2.5 | upsAdvInputLineFailCause | 1 | 1 | The reason for the occurrence of the last transfer to UPS battery power. The variable is set to: - noTransfer(1) - highLineVoltag… |
| 1.3.6.1.4.1.318.1.1.1.3.2.6 | upsAdvInputNominalFrequency | 1 | 1 | The nominal input frequency of the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.3.2.7 | upsAdvInputNominalVoltage | 1 | 1 | The nominal input voltage of the UPS system in VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.2.8 | upsAdvInputBypassNominalFrequency | 1 | 1 | The nominal bypass input frequency of the UPS system in Hz. |
| 1.3.6.1.4.1.318.1.1.1.3.2.9 | upsAdvInputBypassNominalVoltage | 1 | 1 | The nominal bypass input voltage of the UPS system in VAC. |
| 1.3.6.1.4.1.318.1.1.1.3.2.10 | upsAdvInputStatisticsTable | 1 | 8 | A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs. |
| 1.3.6.1.4.1.318.1.1.1.3.2.11 | upsAdvInputTotalApparentPower | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.3.2.13 | upsAdvInputBypassTotalApparentPower | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.3.2.14 | upsAdvInputBypassTotalActivePower | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.3.2.15 | upsAdvInputEnergyUsage | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.3.2.16 | upsAdvInputDCVoltage | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.3.2.17 | upsAdvInputDCCurrent | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.1.3.2.18 | upsAdvInputNominalDCVoltage | 0 | 0 |