emsLeakRopeStatusSeverity — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies
The severity of the alarm that will be triggered when the leak rope is activated.
{1 3 6 1 4 1 318 1 1 10 3 20 10 1 5}
The severity of the alarm that will be triggered when the leak rope is activated.
Status in source: mandatory.
Names: emsLeakRopeStatusSeverity
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"emsLeakRopeStatusSeverity",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"critical",
"(",
"1",
")",
",",
"major",
"(",
"2",
")",
",",
"minor",
"(",
"3",
")",
",",
"warning",
"(",
"4",
")",
",",
"informational",
"(",
"5",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The severity of the alarm that will be triggered when the leak rope is activated.\"",
"::=",
"{",
"emsLeakRopeStatusEntry",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"critical",
1
],
[
"major",
2
],
[
"minor",
3
],
[
"warning",
4
],
[
"informational",
5
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The severity of the alarm that will be triggered when the leak rope is activated."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PowerNet-MIB
emsLeakRopeStatusSeverity OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
warning(4),
informational(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The severity of the alarm that will be triggered when the leak rope is activated."
::= { emsLeakRopeStatusEntry 5 }{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.503326+00:00.
Vendor MIB copy from the Netdisco archive.
Module: PowerNet-MIB
emsLeakRopeStatusSeverity OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
warning(4),
informational(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The severity of the alarm that will be triggered when the leak rope is activated."
::= { emsLeakRopeStatusEntry 5 }{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Downloaded: 2026-10-24T15:28:08.582017+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.10.3.20.10.1.1 | emsLeakRopeStatusIndex | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.3.20.10.1.2 | emsLeakRopeStatusName | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.3.20.10.1.3 | emsLeakRopeStatusLocation | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.3.20.10.1.4 | emsLeakRopeStatusState | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.3.20.10.1.6 | emsLeakRopeCommStatus | 0 | 0 |