memFluidSensorConfigSensorName — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies
The user defined name of the fluid sensor.
{1 3 6 1 4 1 318 1 1 10 4 7 11 1 3}
The user defined name of the fluid sensor.
Status in source: mandatory.
Names: memFluidSensorConfigSensorName
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"memFluidSensorConfigSensorName",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The user defined name of the fluid sensor.\"",
"::=",
"{",
"memFluidSensorConfigEntry",
"3",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The user defined name of the fluid sensor."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PowerNet-MIB
memFluidSensorConfigSensorName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user defined name of the fluid sensor."
::= { memFluidSensorConfigEntry 3 }{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.503326+00:00.
Vendor MIB copy from the Observium Community archive.
Module: PowerNet-MIB
memFluidSensorConfigSensorName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user defined name of the fluid sensor."
::= { memFluidSensorConfigEntry 3 }{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Downloaded: 2026-10-24T02:14:28.042136+00:00.
Vendor MIB copy from the Netdisco archive.
Module: PowerNet-MIB
memFluidSensorConfigSensorName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user defined name of the fluid sensor."
::= { memFluidSensorConfigEntry 3 }{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Downloaded: 2026-10-24T15:28:08.582017+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.1 | memFluidSensorModuleConfigIndex | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.2 | memFluidSensorConfigSensorIndex | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.4 | memFluidSensorConfigSensorLocation | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.5 | memFluidSensorConfigSensorSeverity | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.10.4.7.11.1.6 | memFluidSensorConfigAlarmGeneration | 0 | 0 |