The UPS battery run time remaining before battery exhaustion.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.318.1.1.31.2.4.1.1.2
The UPS battery run time remaining before battery exhaustion.
Identification
{1 3 6 1 4 1 318 1 1 31 2 4 1 1 2}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In PowerNet-MIB, the row index mdcUpsBatteryTableIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.318.1.1.31.2.4.1.1.2.<mdcUpsBatteryTableIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.318.1.1.31.2.4.1.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
mdcUpsBatteryRunTimeRemaining OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS battery run time remaining before battery
exhaustion."
::= { mdcUpsBatteryEntry 2 }mdcUpsBatteryRunTimeRemaining OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS battery run time remaining before battery
exhaustion."
::= { mdcUpsBatteryEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The UPS battery run time remaining before battery exhaustion.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: mdcUpsBatteryRunTimeRemaining
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mdcUpsBatteryRunTimeRemaining",
"OBJECT-TYPE",
"SYNTAX",
"TimeTicks",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The UPS battery run time remaining before battery exhaustion.\"",
"::=",
"{",
"mdcUpsBatteryEntry",
"2",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"TimeTicks",
null
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The UPS battery run time remaining before battery exhaustion."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PowerNet-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: PowerNet-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: PowerNet-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.31.2.4.1.1.1 | mdcUpsBatteryTableIndex | 0 | 0 | |
| 1.3.6.1.4.1.318.1.1.31.2.4.1.1.3 | mdcUpsBatteryCapacity | 0 | 0 |