ats5gSwitchEventCountSpikeOrDrop

1.3.6.1.4.1.318.1.1.33.3.1.30

Description

This value tracks voltage spike and drop events. It increments each time a source's measured instantaneous voltage increases or decreases rapidly. This depends on configured voltage sensitivity.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.318.1.1.33.3.1 (ats5gDeviceSwitchEntry)
Node code
30
Node name
ats5gSwitchEventCountSpikeOrDrop
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.318.1.1.33.3.1.30
URN notation
urn:oid:1.3.6.1.4.1.318.1.1.33.3.1.30
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 318 1 1 33 3 1 30}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) apc(318) products(1) hardware(1) ats5g(33) ats5gDeviceSwitchTable(3) ats5gDeviceSwitchEntry(1) ats5gSwitchEventCountSpikeOrDrop(30)}
OID-IRI notation
  • /1/3/6/1/4/1/318/1/1/33/3/1/30
  • /ISO/Identified-Organization/6/1/4/1/318/1/1/33/3/1/30
  • /ISO/3/6/1/4/1/318/1/1/33/3/1/30
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/identified-organization/dod/internet/private/enterprise/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/identified-organization/dod/internet/private/enterprises/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/identified-organization/dod/internet/private/vendor-objects/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/identified-organization/dod/internet/private/vendor-objects/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/enterprise/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/enterprises/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/ldap-enterprise/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/ldap-enterprise/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/vendor-objects/apc/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • /iso/org/dod/internet/private/vendor-objects/PDU/products/hardware/ats5g/ats5gDeviceSwitchTable/ats5gDeviceSwitchEntry/ats5gSwitchEventCountSpikeOrDrop
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In PowerNet-MIB, the row index ats5gSwitchDeviceIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.318.1.1.33.3.1.30.<ats5gSwitchDeviceIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.318.1.1.33.3.1.30

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

ats5gSwitchEventCountSpikeOrDrop · mandatory

ats5gSwitchEventCountSpikeOrDrop OBJECT-TYPE
   SYNTAX INTEGER
   ACCESS read-only
   STATUS mandatory
   DESCRIPTION
      "This value tracks voltage spike and drop events. It increments each time a
       source's measured instantaneous voltage increases or decreases rapidly.
       This depends on configured voltage sensitivity."
   ::= { ats5gDeviceSwitchEntry 30 }

ats5gSwitchEventCountSpikeOrDrop · mandatory

ats5gSwitchEventCountSpikeOrDrop OBJECT-TYPE
   SYNTAX INTEGER
   ACCESS read-only
   STATUS mandatory
   DESCRIPTION
      "This value tracks voltage spike and drop events. It increments each time a
       source's measured instantaneous voltage increases or decreases rapidly.
       This depends on configured voltage sensitivity."
   ::= { ats5gDeviceSwitchEntry 30 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This value tracks voltage spike and drop events. It increments each time a source's measured instantaneous voltage increases or decreases rapidly. This depends on configured voltage sensitivity.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies1 record · 3 sources

Description 1

ats5gSwitchEventCountSpikeOrDrop · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies3 sources

Status in source: mandatory.

Names: ats5gSwitchEventCountSpikeOrDrop

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ats5gSwitchEventCountSpikeOrDrop",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"This value tracks voltage spike and drop events. It increments each time a source's measured instantaneous voltage increases or decreases rapidly. This depends on configured voltage sensitivity.\"",
    "::=",
    "{",
    "ats5gDeviceSwitchEntry",
    "30",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "This value tracks voltage spike and drop events. It increments each time a source's measured instantaneous voltage increases or decreases rapidly. This depends on configured voltage sensitivity."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.318)

Yoest Peter C.

Siblings (40)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.318.1.1.33.3.1.1 ats5gSwitchDeviceIndex00
1.3.6.1.4.1.318.1.1.33.3.1.2 ats5gSwitchModuleID00
1.3.6.1.4.1.318.1.1.33.3.1.3 ats5gSwitchOrientation00
1.3.6.1.4.1.318.1.1.33.3.1.4 ats5gSwitchCumulativeAlarmStatus00
1.3.6.1.4.1.318.1.1.33.3.1.5 ats5gSwitchCommunicationStatus00
1.3.6.1.4.1.318.1.1.33.3.1.6 ats5gSwitchConfigFrontPanelLockout00
1.3.6.1.4.1.318.1.1.33.3.1.7 ats5gSwitchConfigPreferredSource00
1.3.6.1.4.1.318.1.1.33.3.1.8 ats5gSwitchSelectedSource00
1.3.6.1.4.1.318.1.1.33.3.1.9 ats5gSwitchRedundancyState00
1.3.6.1.4.1.318.1.1.33.3.1.10 ats5gSwitchSourceAStatus00
1.3.6.1.4.1.318.1.1.33.3.1.11 ats5gSwitchSourceBStatus00
1.3.6.1.4.1.318.1.1.33.3.1.12 ats5gSwitchRatedVoltage00
1.3.6.1.4.1.318.1.1.33.3.1.13 ats5gSwitchConfigNominalVoltage00
1.3.6.1.4.1.318.1.1.33.3.1.14 ats5gSwitchConfigTransferVoltageRange00
1.3.6.1.4.1.318.1.1.33.3.1.15 ats5gSwitchConfigTransferVoltageWide00
1.3.6.1.4.1.318.1.1.33.3.1.16 ats5gSwitchConfigTransferVoltageMedium00
1.3.6.1.4.1.318.1.1.33.3.1.17 ats5gSwitchConfigTransferVoltageNarrow00
1.3.6.1.4.1.318.1.1.33.3.1.18 ats5gSwitchConfigVoltageSensitivity00
1.3.6.1.4.1.318.1.1.33.3.1.19 ats5gSwitchSourceAVoltage00
1.3.6.1.4.1.318.1.1.33.3.1.20 ats5gSwitchSourceBVoltage00
1.3.6.1.4.1.318.1.1.33.3.1.21 ats5gSwitchRatedFrequency00
1.3.6.1.4.1.318.1.1.33.3.1.22 ats5gSwitchConfigNominalFrequency00
1.3.6.1.4.1.318.1.1.33.3.1.23 ats5gSwitchConfigFrequencyDeviation00
1.3.6.1.4.1.318.1.1.33.3.1.24 ats5gSwitchSourceAFrequency00
1.3.6.1.4.1.318.1.1.33.3.1.25 ats5gSwitchSourceBFrequency00
1.3.6.1.4.1.318.1.1.33.3.1.26 ats5gSwitchEventCountStartTime00
1.3.6.1.4.1.318.1.1.33.3.1.27 ats5gSwitchEventCountRedundancyLoss00
1.3.6.1.4.1.318.1.1.33.3.1.28 ats5gSwitchEventCountSourceSwitch00
1.3.6.1.4.1.318.1.1.33.3.1.29 ats5gSwitchEventCountSourcePrefChange00
1.3.6.1.4.1.318.1.1.33.3.1.31 ats5gSwitchEventCountSurgeOrDroop00
1.3.6.1.4.1.318.1.1.33.3.1.32 ats5gSwitchEventCountFreqOutOfRange00
1.3.6.1.4.1.318.1.1.33.3.1.33 ats5gSwitchControlEventCountReset00
1.3.6.1.4.1.318.1.1.33.3.1.34 ats5gSwitchVoltageOutStatus00
1.3.6.1.4.1.318.1.1.33.3.1.35 ats5gSwitchOverCurrentState00
1.3.6.1.4.1.318.1.1.33.3.1.36 ats5gSwitchPhaseSyncStatus00
1.3.6.1.4.1.318.1.1.33.3.1.37 ats5gSwitchSourceA24VSupplyStatus00
1.3.6.1.4.1.318.1.1.33.3.1.38 ats5gSwitchSourceB24VSupplyStatus00
1.3.6.1.4.1.318.1.1.33.3.1.39 ats5gSwitchSourceA48VSupplyStatus00
1.3.6.1.4.1.318.1.1.33.3.1.40 ats5gSwitchSourceB48VSupplyStatus00
1.3.6.1.4.1.318.1.1.33.3.1.41 ats5gSwitch3p3VSupplyStatus00