OID reference

cableTestConfigReflectionHysteresis

1.3.6.1.4.1.3181.10.6.1.31.6.1.5

Description

Choose value to prevent oscillation when reflection value is slightly shifting. For OTDR measurement, the value is interpreted as minimum meters of change in a reflection for it to be considered a different reflection.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3181.10.6.1.31.6.1 (cableTestConfigEntry)
Node code
5
Node name
cableTestConfigReflectionHysteresis
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3181.10.6.1.31.6.1.5
URN notation
urn:oid:1.3.6.1.4.1.3181.10.6.1.31.6.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3181 10 6 1 31 6 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) microsens(3181) managedSwitches(10) g6(6) device(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) microsens(3181) managedSwitches(10) g6(6) g6TrapGroup(1) hardware(31) cableTestConfigTable(6) cableTestConfigEntry(1) cableTestConfigReflectionHysteresis(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3181/10/6/1/31/6/1/5
  • /ISO/Identified-Organization/6/1/4/1/3181/10/6/1/31/6/1/5
  • /ISO/3/6/1/4/1/3181/10/6/1/31/6/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/identified-organization/dod/internet/private/enterprise/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/identified-organization/dod/internet/private/enterprises/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/identified-organization/dod/internet/private/enterprises/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/identified-organization/dod/internet/private/vendor-objects/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/identified-organization/dod/internet/private/vendor-objects/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/enterprise/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/enterprise/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/enterprises/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/enterprises/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/ldap-enterprise/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/ldap-enterprise/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/vendor-objects/microsens/managedSwitches/g6/device/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • /iso/org/dod/internet/private/vendor-objects/microsens/managedSwitches/g6/g6TrapGroup/hardware/cableTestConfigTable/cableTestConfigEntry/cableTestConfigReflectionHysteresis
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
0–65535

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In G6-HARDWARE-MIB, the row index cableTestConfigPortIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.3181.10.6.1.31.6.1.5.<cableTestConfigPortIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3181.10.6.1.31.6.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

cableTestConfigReflectionHysteresis · current

cableTestConfigReflectionHysteresis OBJECT-TYPE   -- reflection_hysteresis
	SYNTAX Integer32 (0..65535)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Choose value to prevent oscillation when reflection value is slightly shifting. For OTDR measurement, the value is interpreted as minimum meters of change in a reflection for it to be considered a different reflection."
	::= { cableTestConfigEntry 5 }

cableTestConfigReflectionHysteresis · current

cableTestConfigReflectionHysteresis OBJECT-TYPE   -- reflection_hysteresis
	SYNTAX Integer32 (0..65535)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Choose value to prevent oscillation when reflection value is slightly shifting."
	::= { cableTestConfigEntry 5 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Choose value to prevent oscillation when reflection value is slightly shifting. For OTDR measurement, the value is interpreted as minimum meters of change in a reflection for it to be considered a different reflection.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

Choose value to prevent oscillation when reflection value is slightly shifting.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

cableTestConfigReflectionHysteresis · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: cableTestConfigReflectionHysteresis

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cableTestConfigReflectionHysteresis",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Choose value to prevent oscillation when reflection value is slightly shifting. For OTDR measurement, the value is interpreted as minimum meters of change in a reflection for it to be considered a different reflection.\"",
    "::=",
    "{",
    "cableTestConfigEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Choose value to prevent oscillation when reflection value is slightly shifting. For OTDR measurement, the value is interpreted as minimum meters of change in a reflection for it to be considered a different reflection."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies1 record · 2 sources

Description 2

cableTestConfigReflectionHysteresis · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies2 sources

Status in source: current.

Names: cableTestConfigReflectionHysteresis

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cableTestConfigReflectionHysteresis",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Choose value to prevent oscillation when reflection value is slightly shifting.\"",
    "::=",
    "{",
    "cableTestConfigEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Choose value to prevent oscillation when reflection value is slightly shifting."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3181)

Hannes Bauer

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3181.10.6.1.31.6.1.1 cableTestConfigPortIndex00
1.3.6.1.4.1.3181.10.6.1.31.6.1.2 cableTestConfigEnableAutoCableTest00
1.3.6.1.4.1.3181.10.6.1.31.6.1.3 cableTestConfigEventGeneration00
1.3.6.1.4.1.3181.10.6.1.31.6.1.4 cableTestConfigReflectionThreshold00
1.3.6.1.4.1.3181.10.6.1.31.6.1.6 cableTestConfigStartTestNow00
1.3.6.1.4.1.3181.10.6.1.31.6.1.7 cableTestConfigCreateReference00
1.3.6.1.4.1.3181.10.6.1.31.6.1.8 cableTestConfigReferenceData00