Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"configFailureDetection",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"bothPorts",
"(",
"0",
")",
",",
"portA",
"(",
"1",
")",
",",
"portB",
"(",
"2",
")",
",",
"none",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"For normal ring applications set detection to BOTH_PORTS. Other settings are required when two rings are coupled with 2 parallel links for redundant inter-ring traffic. In this case not all links should be monitored in order to avoid a possible loop condition. Careful planning is advised.\"",
"::=",
"{",
"configEntry",
"8",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"bothPorts",
0
],
[
"portA",
1
],
[
"portB",
2
],
[
"none",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"For normal ring applications set detection to BOTH_PORTS. Other settings are required when two rings are coupled with 2 parallel links for redundant inter-ring traffic. In this case not all links should be monitored in order to avoid a possible loop condition. Careful planning is advised."
],
null,
null,
null,
null
]
}