The total length of the management address subtype and the management address fields in LLDPDUs transmitted by the local LLDP agent. The management address length field is needed so that the receiving systems that do not implement SNMP will not be required to implement an iana family numbers/address length equivalency…
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
Documented MIB packages
The FS.COM catalogue lists MIB packages containing this definition for these models:
A definition in a model's MIB package does not establish that the device implements it or permits access.
Published definitions
Available source records contain 2 distinct definitions; some records may not include a definition.
Show 2 published definitions
lldpLocManAddrLen · current
lldpLocManAddrLen OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total length of the management address subtype and the
management address fields in LLDPDUs transmitted by the
local LLDP agent.
The management address length field is needed so that the
receiving systems that do not implement SNMP will not be
required to implement an iana family numbers/address length
equivalency table in order to decode the management adress."
REFERENCE
"IEEE 802.1AB-2004 9.5.9.2"
::= { lldpLocManAddrEntry 3 }
lldpLocManAddrLen · current
lldpLocManAddrLen OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total length of the management address subtype and the
management address fields in LLDPDUs transmitted by the
local LLDP agent.
The management address length field is needed so that the
receiving systems that do not implement SNMP will not be
required to implement an iana family numbers/address length
equivalency table in order to decode the management adress."
REFERENCE
"IEEE 802.1AB-2004 9.5.9.2"
::= { lldpLocManAddrEntry 3 }
Meaning
Descriptions
1 unique
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The total length of the management address subtype and the management address fields in LLDPDUs transmitted by the local LLDP agent. The management address length field is needed so that the receiving systems that do not implement SNMP will not be required to implement an iana family numbers/address length equivalency table in order to decode the management adress.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)FS.COM official Documentation Hub native MIB packages
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), FS.COM official Documentation Hub native MIB packages1 record · 3 sources
lldpLocManAddrLen · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), FS.COM official Documentation Hub native MIB packages3 sources
Status in source: current.
Names: lldpLocManAddrLen
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"lldpLocManAddrLen",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The total length of the management address subtype and the management address fields in LLDPDUs transmitted by the local LLDP agent. The management address length field is needed so that the receiving systems that do not implement SNMP will not be required to implement an iana family numbers/address length equivalency table in order to decode the management adress.\"",
"REFERENCE",
"\"IEEE 802.1AB-2004 9.5.9.2\"",
"::=",
"{",
"lldpLocManAddrEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The total length of the management address subtype and the management address fields in LLDPDUs transmitted by the local LLDP agent. The management address length field is needed so that the receiving systems that do not implement SNMP will not be required to implement an iana family numbers/address length equivalency table in order to decode the management adress."
],
[
"REFERENCE",
"IEEE 802.1AB-2004 9.5.9.2"
],
null,
null,
null
]
}