Description 1
Sources for this description
OID Repository
View at oid-base.comModule: BDCOM-IF-THRESHOLD-MIB
[Automatically extracted from oidview.com]
OID reference
1.3.6.1.4.1.3320.9.218.1.1.3.1
Identification
{1 3 6 1 4 1 3320 9 218 1 1 3 1}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The FS.COM catalogue lists MIB packages containing this definition for these models:
IES3100-16TM, IES3100-8T4F-P, IES3100-8TF, IES3100-8TF-P, S3150-8T2FP, S3260-8T2FP, S3400-24T4FP, S3400-24T4SP, S3400-48T4SP, S3400-48T6SP, S3700-24T4F, S3900-24F4S-R.
S3900-24T4S-R, S3900-48T6S-R, S5500-24TF6S, S5500-48F6S, S5500-48T6S, S5500-48T6SP-R, S5900-24S4T2Q.
A definition in a model's MIB package does not establish that the device implements it or permits access.
The displayed source records contain one distinct definition. Compare its source records.
nmsifthTemplateEntry OBJECT-TYPE
SYNTAX NMSifthTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describing the general properties of a threshold
template.
The template is created using the nmsifthTemplateRowStatus
object. Prior to creating an entry in the table, the manager
should obtain a unique value of nmsifthTemplateIndex by reading
the nmsifthTemplateIndexNext object. The values of
nmsifthTemplateName and nmsifthTemplateNotifyHoldDownType must be
provided before activating the entry.
After creating an entry, thresholds can be defined for the
template by creating entries with the same value of
nmsifthTemplateIndex in the nmsifthThresholdTable. The template
can then be assigned to one or more interfaces using the
nmsifthTemplateIfAssignTable.
Once an entry has been activated, the value of
nmsifthTemplateName cannot be modified. In order to use a new
value of nmsifthTemplateName, a new template must be defined.
The values of nmsifthTemplateNotifyHoldDownType and
nmsifthTemplateNotifyHoldDownTime may be modified when the entry
is active. See the description clause of
nmsifthTemplateNotifyHoldDownType for further caveats on
modification of that object."
INDEX { nmsifthTemplateIndex }
::= { nmsifthTemplateTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Description 2
Parsed from BDCOM-IF-THRESHOLD-MIB.mib · BDCOM-IF-THRESHOLD-MIB
Source file: Download BDCOM-IF-THRESHOLD-MIB · Publisher's file
Vendor MIB copy from the Observium Community archive.
Related source files and packages:
Source file: Download BDCOM-IF-THRESHOLD-MIB.mib
Description 3
An entry describing the general properties of a threshold template. The template is created using the nmsifthTemplateRowStatus object. Prior to creating an entry in the table, the manager should obtain a unique value of nmsifthTemplateIndex by reading the nmsifthTemplateIndexNext object. The values of nmsifthTemplateName and nmsifthTemplateNotifyHoldDownType must be provided before activating the entry. After creating an entry, thresholds can be defined for the template by creating entries with the same value of nmsifthTemplateIndex in the nmsifthThresholdTable. The template can then be assigned to one or more interfaces using the nmsifthTemplateIfAssignTable. Once an entry has been activated, the value of nmsifthTemplateName cannot be modified. In order to use a new value of nmsifthTemplateName, a new template must be defined. The values of nmsifthTemplateNotifyHoldDownType and nmsifthTemplateNotifyHoldDownTime may be modified when the entry is active. See the description clause of nmsifthTemplateNotifyHoldDownType for further caveats on modification of that object.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)FS.COM official Documentation Hub native MIB packages
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: nmsifthTemplateEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"nmsifthTemplateEntry",
"OBJECT-TYPE",
"SYNTAX",
"NMSifthTemplateEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"An entry describing the general properties of a threshold template. The template is created using the nmsifthTemplateRowStatus object. Prior to creating an entry in the table, the manager should obtain a unique value of nmsifthTemplateIndex by reading the nmsifthTemplateIndexNext object. The values of nmsifthTemplateName and nmsifthTemplateNotifyHoldDownType must be provided before activating the entry. After creating an entry, thresholds can be defined for the template by creating entries with the same value of nmsifthTemplateIndex in the nmsifthThresholdTable. The template can then be assigned to one or more interfaces using the nmsifthTemplateIfAssignTable. Once an entry has been activated, the value of nmsifthTemplateName cannot be modified. In order to use a new value of nmsifthTemplateName, a new template must be defined. The values of nmsifthTemplateNotifyHoldDownType and nmsifthTemplateNotifyHoldDownTime may be modified when the entry is active. See the description clause of nmsifthTemplateNotifyHoldDownType for further caveats on modification of that object.\"",
"INDEX",
"{",
"nmsifthTemplateIndex",
"}",
"::=",
"{",
"nmsifthTemplateTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"NMSifthTemplateEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"An entry describing the general properties of a threshold template. The template is created using the nmsifthTemplateRowStatus object. Prior to creating an entry in the table, the manager should obtain a unique value of nmsifthTemplateIndex by reading the nmsifthTemplateIndexNext object. The values of nmsifthTemplateName and nmsifthTemplateNotifyHoldDownType must be provided before activating the entry. After creating an entry, thresholds can be defined for the template by creating entries with the same value of nmsifthTemplateIndex in the nmsifthThresholdTable. The template can then be assigned to one or more interfaces using the nmsifthTemplateIfAssignTable. Once an entry has been activated, the value of nmsifthTemplateName cannot be modified. In order to use a new value of nmsifthTemplateName, a new template must be defined. The values of nmsifthTemplateNotifyHoldDownType and nmsifthTemplateNotifyHoldDownTime may be modified when the entry is active. See the description clause of nmsifthTemplateNotifyHoldDownType for further caveats on modification of that object."
],
null,
null,
[
"INDEX",
[
[
0,
"nmsifthTemplateIndex"
]
]
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: NMS-IF-THRESHOLD-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'NMS-SMI': ['nmsMgmt'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Module: NMS-IF-THRESHOLD-MIB
{'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'NMS-SMI': ['nmsMgmt'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in 20230724154543a6vsk6.zip.
Same file in s5500-series-switches-snmp-mib-files.zip.
Same file in s3260-8t2fp-switch-snmp-mib-files.zip.
Same file in s3150-8t2fp-switch-snmp-mib-files.zip.
Historical records
bdifthTemplateEntry OBJECT-TYPE
SYNTAX BdifthTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describing the general properties of a threshold
template.
The template is created using the bdifthTemplateRowStatus
object. Prior to creating an entry in the table, the manager
should obtain a unique value of bdifthTemplateIndex by reading
the bdifthTemplateIndexNext object. The values of
bdifthTemplateName and bdifthTemplateNotifyHoldDownType must be
provided before activating the entry.
After creating an entry, thresholds can be defined for the
template by creating entries with the same value of
bdifthTemplateIndex in the bdifthThresholdTable. The template
can then be assigned to one or more interfaces using the
bdifthTemplateIfAssignTable.
Once an entry has been activated, the value of
bdifthTemplateName cannot be modified. In order to use a new
value of bdifthTemplateName, a new template must be defined.
The values of bdifthTemplateNotifyHoldDownType and
bdifthTemplateNotifyHoldDownTime may be modified when the entry
is active. See the description clause of
bdifthTemplateNotifyHoldDownType for further caveats on
modification of that object."
INDEX { bdifthTemplateIndex }
::= { bdifthTemplateTable 1 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3320.9.218.1.1.3.1.1 | bdifthTemplateIndex, nmsifthTemplateIndex | 0 | 0 | bdifthtemplateIndex |
| 1.3.6.1.4.1.3320.9.218.1.1.3.1.2 | bdifthTemplateName, nmsifthTemplateName | 0 | 0 | bdifthtemplateName |
| 1.3.6.1.4.1.3320.9.218.1.1.3.1.3 | bdifthTemplateNotifyHoldDownType, nmsifthTemplateNotifyHoldDownType | 0 | 0 | bdifthtemplateNotifyHoldDownType |
| 1.3.6.1.4.1.3320.9.218.1.1.3.1.4 | bdifthTemplateNotifyHoldDownTime, nmsifthTemplateNotifyHoldDownTime | 0 | 0 | bdifthtemplateNotifyHoldDownTime |
| 1.3.6.1.4.1.3320.9.218.1.1.3.1.5 | bdifthTemplateRowStatus, nmsifthTemplateRowStatus | 0 | 0 | bdifthtemplateRowStatus |