Force Equipment Controller restart or change in interface properties.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3373.1103.1.16
Force Equipment Controller restart or change in interface properties.
Identification
{1 3 6 1 4 1 3373 1103 1 16}
Notes below names come from selected MIB definitions.
| Value | Name and source notes |
|---|---|
| 0 | notActive no write-only in v2 |
| 1 | restart |
| 2 | applyIfChange |
| 3 | revertIfChange |
| 4 | configClearAndRestart |
| 5 | routeTableClear |
| 6 | uploadBaseBand |
| 7 | offLineRouteRetrieve |
| 8 | offLineRouteSave |
| 11 | hotApplyIfChange |
| 20 | ipStackConfigure |
| 21 | osiStackConfigure |
| 50 | atuTableReset |
| 100 | siaeReservedReq1 |
| 125 | siaeReservedReq26 |
| 126 | siaeReservedReq27 |
| 127 | switchFactoryDefault |
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
equipRequest OBJECT-TYPE
SYNTAX INTEGER {
notActive (0), -- no write-only in v2
restart (1),
applyIfChange (2),
revertIfChange (3),
configClearAndRestart (4),
routeTableClear (5),
uploadBaseBand (6),
offLineRouteRetrieve (7),
offLineRouteSave (8),
hotApplyIfChange (11),
ipStackConfigure (20),
osiStackConfigure (21),
atuTableReset (50),
siaeReservedReq1 (100),
siaeReservedReq26 (125),
siaeReservedReq27 (126),
switchFactoryDefault (127)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force Equipment Controller restart or change in interface properties."
::= {equipment 16}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Force Equipment Controller restart or change in interface properties.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: equipRequest
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"equipRequest",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"notActive",
"(",
"0",
")",
",",
"restart",
"(",
"1",
")",
",",
"applyIfChange",
"(",
"2",
")",
",",
"revertIfChange",
"(",
"3",
")",
",",
"configClearAndRestart",
"(",
"4",
")",
",",
"routeTableClear",
"(",
"5",
")",
",",
"uploadBaseBand",
"(",
"6",
")",
",",
"offLineRouteRetrieve",
"(",
"7",
")",
",",
"offLineRouteSave",
"(",
"8",
")",
",",
"hotApplyIfChange",
"(",
"11",
")",
",",
"ipStackConfigure",
"(",
"20",
")",
",",
"osiStackConfigure",
"(",
"21",
")",
",",
"atuTableReset",
"(",
"50",
")",
",",
"siaeReservedReq1",
"(",
"100",
")",
",",
"siaeReservedReq26",
"(",
"125",
")",
",",
"siaeReservedReq27",
"(",
"126",
")",
",",
"switchFactoryDefault",
"(",
"127",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Force Equipment Controller restart or change in interface properties.\"",
"::=",
"{",
"equipment",
"16",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"notActive",
0
],
[
"restart",
1
],
[
"applyIfChange",
2
],
[
"revertIfChange",
3
],
[
"configClearAndRestart",
4
],
[
"routeTableClear",
5
],
[
"uploadBaseBand",
6
],
[
"offLineRouteRetrieve",
7
],
[
"offLineRouteSave",
8
],
[
"hotApplyIfChange",
11
],
[
"ipStackConfigure",
20
],
[
"osiStackConfigure",
21
],
[
"atuTableReset",
50
],
[
"siaeReservedReq1",
100
],
[
"siaeReservedReq26",
125
],
[
"siaeReservedReq27",
126
],
[
"switchFactoryDefault",
127
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Force Equipment Controller restart or change in interface properties."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SIAE-EQUIP-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['DisplayString', 'AutonomousType'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Integer32', 'IpAddress', 'TimeTicks'], 'SIAE-TREE-MIB': ['siaeMib'], 'SIAE-ALARM-MIB': ['AlarmStatus', 'AlarmSeverityCode', 'alarmTrap'], 'SIAE-EQUIPTYPE-MIB': ['equipTypeUnknown']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SIAE-EQUIP-MIB
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['DisplayString', 'AutonomousType'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Integer32', 'IpAddress', 'TimeTicks'], 'SIAE-TREE-MIB': ['siaeMib'], 'SIAE-ALARM-MIB': ['AlarmStatus', 'AlarmSeverityCode', 'alarmTrap'], 'SIAE-EQUIPTYPE-MIB': ['equipTypeUnknown']}Related source files and packages:
Registration