Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ptpClockLocalPriority",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"1",
".",
".",
"255",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This attribute is used in the alternate BMCA as a tie-breaker in the dataset comparison algorithm, in the event that all other previous attributes of the datasets being compared are equal.\"",
"REFERENCE",
"\"Section 6.3.1 and 6.3.2 of [2]\"",
"DEFVAL",
"{",
"128",
"}",
"::=",
"{",
"ptpClockDataSetEntry",
"13",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
1,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This attribute is used in the alternate BMCA as a tie-breaker in the dataset comparison algorithm, in the event that all other previous attributes of the datasets being compared are equal."
],
[
"REFERENCE",
"Section 6.3.1 and 6.3.2 of [2]"
],
null,
null,
[
"DEFVAL",
128
]
]
}