This object specifies the Baudrate of ToD signal in input or output direction.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3373.1103.100.9.1.1.11
This object specifies the Baudrate of ToD signal in input or output direction.
Identification
{1 3 6 1 4 1 3373 1103 100 9 1 1 11}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: ptpClockDomainIndex, ptpClockTypeIndex, ptpClockInstanceIndex, ptpClockPPSInstanceIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3373.1103.100.9.1.1.11
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
ptpClockToDBaudrate OBJECT-TYPE
SYNTAX Unsigned32 (300|600|1200|1800|2400|4800|9600|19200|38400|57600|115200|230400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the Baudrate of ToD signal in input or output direction."
DEFVAL { 9600 }
::= { ptpClockPPSDataSetEntry 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object specifies the Baudrate of ToD signal in input or output direction.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: ptpClockToDBaudrate
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ptpClockToDBaudrate",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"300",
"|",
"600",
"|",
"1200",
"|",
"1800",
"|",
"2400",
"|",
"4800",
"|",
"9600",
"|",
"19200",
"|",
"38400",
"|",
"57600",
"|",
"115200",
"|",
"230400",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object specifies the Baudrate of ToD signal in input or output direction.\"",
"DEFVAL",
"{",
"9600",
"}",
"::=",
"{",
"ptpClockPPSDataSetEntry",
"11",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
300
],
[
600
],
[
1200
],
[
1800
],
[
2400
],
[
4800
],
[
9600
],
[
19200
],
[
38400
],
[
57600
],
[
115200
],
[
230400
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object specifies the Baudrate of ToD signal in input or output direction."
],
null,
null,
null,
[
"DEFVAL",
9600
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: SIAE-PTP-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SIAE-TREE-MIB': ['siaeMib'], 'SIAE-ALARM-MIB': ['AlarmStatus', 'AlarmSeverityCode']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3373.1103.100.9.1.1.1 | ptpClockPPSInstanceIndex | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.2 | ptpClockPPSInstanceCapability | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.3 | ptpClockPPSDirection | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.4 | ptpClockPPSLabel | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.5 | ptpClockPPSAdminStatus | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.6 | ptpClockPPSOffsetEnabled | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.7 | ptpClockPPSOffsetValue | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.8 | ptpClockToDLabel | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.9 | ptpClockToDAdminStatus | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.10 | ptpClockToDDelay | 0 | 0 | |
| 1.3.6.1.4.1.3373.1103.100.9.1.1.12 | ptpClockToDFormat | 0 | 0 |