cbVoltBad
Numeric OID
1.3.6.1.4.1.34.0.41
URN notation
urn:oid:1.3.6.1.4.1.34.0.41
ASN.1 notation

{1 3 6 1 4 1 34 0 41}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cray(34) 0 cbVoltBad(41)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cray(34) 0 cbVoltBad(41)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cray(34) 0 cbVoltBad(41)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cray(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cray(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cray(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cray(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) sun(34) 0 cbVoltBad(41)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cray(34) 0 cbVoltBad(41)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/34/0/41
  • /ISO/Identified-Organization/6/1/4/1/34/0/41
  • /ISO/3/6/1/4/1/34/0/41
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/sun/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/enterprise/Cray/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/enterprise/cray/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/enterprises/sun/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/enterprises/Cray/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/enterprises/cray/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/sun/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Cray/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cray/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/vendor-objects/sun/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/vendor-objects/Cray/0/cbVoltBad
  • /iso/identified-organization/dod/internet/private/vendor-objects/cray/0/cbVoltBad
  • /iso/org/dod/internet/private/enterprise/sun/0/cbVoltBad
  • /iso/org/dod/internet/private/enterprise/Cray/0/cbVoltBad
  • /iso/org/dod/internet/private/enterprise/cray/0/cbVoltBad
  • /iso/org/dod/internet/private/enterprises/sun/0/cbVoltBad
  • Additional combinations skipped.

Source records

This trap indicates a Control Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The platform name and board number variables will always be provided with this trap. Whereas, only those voltage readings that crossed the threshold will be included.

Status in source: unspecified.

Names: cbVoltBad

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cbVoltBad",
    "TRAP-TYPE",
    "ENTERPRISE",
    "sun",
    "VARIABLES",
    "{",
    "platformName",
    ",",
    "cbStarfireNum",
    ",",
    "cbStarfire5VDC",
    ",",
    "cbStarfire5VDCHK",
    ",",
    "cbStarfire3p3VDCHK",
    ",",
    "cbStarfire5VDCPer",
    ",",
    "cbStarfire5VDCFan",
    "}",
    "DESCRIPTION",
    "\"This trap indicates a Control Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The platform name and board number variables will always be provided with this trap. Whereas, only those voltage readings that crossed the threshold will be included.\"",
    "::=",
    "41"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "sun"
      ]
    ],
    [
      "VarTypes",
      [
        "platformName",
        "cbStarfireNum",
        "cbStarfire5VDC",
        "cbStarfire5VDCHK",
        "cbStarfire3p3VDCHK",
        "cbStarfire5VDCPer",
        "cbStarfire5VDCFan"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap indicates a Control Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The platform name and board number variables will always be provided with this trap. Whereas, only those voltage readings that crossed the threshold will be included."
    ],
    null
  ]
}
  • Preserved mibdepot archive · Archived source file
    Source location: CRI-SERVER-MIB::cbVoltBad.
    Source version and references

    Archived: 2026-10-19T00:22:07.919155+00:00. SHA-256: 3c1bb61a6c80f3d6911427dfe727d1375c896bbfe4543073426cab0168eb8490

    {'kind': 'TRAP-TYPE', 'details': {'module': 'CRI-SERVER-MIB', 'imports': {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}, 'smi_kind': 'TRAP-TYPE', 'definition': 'cbVoltBad TRAP-TYPE\n\t\tENTERPRISE\tsun\n\t\tVARIABLES \t{ platformName,\n\t\t\t\t  cbStarfireNum,\n\t\t\t\t  cbStarfire5VDC,\n\t\t\t\t  cbStarfire5VDCHK,\n\t\t\t\t  cbStarfire3p3VDCHK,\n\t\t\t\t  cbStarfire5VDCPer,\n\t\t\t\t  cbStarfire5VDCFan\n\t\t\t\t}\n\t\tDESCRIPTION\t"This trap indicates a Control Board bad\n\t\t\t\tvoltage reading. This means that at least\n\t\t\t\thalf the voltage sensors on the board\n\t\t\t\treport invalid voltage readings. The platform\t\n\t\t\t\tname and board number variables will always be\n\t\t\t\tprovided with this trap. Whereas, only those\n\t\t\t\tvoltage readings that crossed the\n\t\t\t\tthreshold will be included."\n\t\t::= 41', 'syntax_tree': [['objectIdentifier', ['sun']], ['VarTypes', ['platformName', 'cbStarfireNum', 'cbStarfire5VDC', 'cbStarfire5VDCHK', 'cbStarfire3p3VDCHK', 'cbStarfire5VDCPer', 'cbStarfire5VDCFan']], ['DESCRIPTION', 'This trap indicates a Control Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The platform name and board number variables will always be provided with this trap. Whereas, only those voltage readings that crossed the threshold will be included.'], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • Preserved mibdepot archive · Archived source file
    Source location: CRI-SERVER-MIB::cbVoltBad.
    Source version and references

    Archived: 2026-10-19T00:22:12.146057+00:00. SHA-256: 73d0eda4dbdd3d68f5b9554c69e13d05957b7b7eb71731f45bd67938323b6bbf

    {'kind': 'TRAP-TYPE', 'details': {'module': 'CRI-SERVER-MIB', 'imports': {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}, 'smi_kind': 'TRAP-TYPE', 'definition': 'cbVoltBad TRAP-TYPE\r\n\t\tENTERPRISE\tsun\r\n\t\tVARIABLES \t{ platformName,\r\n\t\t\t\t  cbStarfireNum,\r\n\t\t\t\t  cbStarfire5VDC,\r\n\t\t\t\t  cbStarfire5VDCHK,\r\n\t\t\t\t  cbStarfire3p3VDCHK,\r\n\t\t\t\t  cbStarfire5VDCPer,\r\n\t\t\t\t  cbStarfire5VDCFan\r\n\t\t\t\t}\r\n\t\tDESCRIPTION\t"This trap indicates a Control Board bad\r\n\t\t\t\tvoltage reading. This means that at least\r\n\t\t\t\thalf the voltage sensors on the board\r\n\t\t\t\treport invalid voltage readings. The platform\t\r\n\t\t\t\tname and board number variables will always be\r\n\t\t\t\tprovided with this trap. Whereas, only those\r\n\t\t\t\tvoltage readings that crossed the\r\n\t\t\t\tthreshold will be included."\r\n\t\t::= 41', 'syntax_tree': [['objectIdentifier', ['sun']], ['VarTypes', ['platformName', 'cbStarfireNum', 'cbStarfire5VDC', 'cbStarfire5VDCHK', 'cbStarfire3p3VDCHK', 'cbStarfire5VDCPer', 'cbStarfire5VDCFan']], ['DESCRIPTION', 'This trap indicates a Control Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The platform name and board number variables will always be provided with this trap. Whereas, only those voltage readings that crossed the threshold will be included.'], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • Preserved circitor archive · Archived source file
    Source location: CRI-SERVER-MIB::cbVoltBad.
    Source version and references

    Archived: 2026-10-19T00:22:16.843042+00:00. SHA-256: 36b88ff1a01d7a79364c7bd15f81df48d8bbb2bec8169113b90fd138476107d8

    {'kind': 'TRAP-TYPE', 'details': {'module': 'CRI-SERVER-MIB', 'imports': {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Counter']}, 'smi_kind': 'TRAP-TYPE', 'definition': 'cbVoltBad TRAP-TYPE\r\n\t\tENTERPRISE\tsun\r\n\t\tVARIABLES \t{ platformName,\r\n\t\t\t\t  cbStarfireNum,\r\n\t\t\t\t  cbStarfire5VDC,\r\n\t\t\t\t  cbStarfire5VDCHK,\r\n\t\t\t\t  cbStarfire3p3VDCHK,\r\n\t\t\t\t  cbStarfire5VDCPer,\r\n\t\t\t\t  cbStarfire5VDCFan\r\n\t\t\t\t}\r\n\t\tDESCRIPTION\t"This trap indicates a Control Board bad\r\n\t\t\t\tvoltage reading. This means that at least\r\n\t\t\t\thalf the voltage sensors on the board\r\n\t\t\t\treport invalid voltage readings. The platform\t\r\n\t\t\t\tname and board number variables will always be\r\n\t\t\t\tprovided with this trap. Whereas, only those\r\n\t\t\t\tvoltage readings that crossed the\r\n\t\t\t\tthreshold will be included."\r\n\t\t::= 41', 'syntax_tree': [['objectIdentifier', ['sun']], ['VarTypes', ['platformName', 'cbStarfireNum', 'cbStarfire5VDC', 'cbStarfire5VDCHK', 'cbStarfire3p3VDCHK', 'cbStarfire5VDCPer', 'cbStarfire5VDCFan']], ['DESCRIPTION', 'This trap indicates a Control Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The platform name and board number variables will always be provided with this trap. Whereas, only those voltage readings that crossed the threshold will be included.'], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q1'}

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.34)

Engineer Hunaid

Siblings (73)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.34.0.0 domainChange00
1.3.6.1.4.1.34.0.1 eddControl00
1.3.6.1.4.1.34.0.2 eddState00
1.3.6.1.4.1.34.0.3 sysBrdTempNorm00
1.3.6.1.4.1.34.0.4 sysBrdTempHigh00
1.3.6.1.4.1.34.0.5 sysBrdTempWarn00
1.3.6.1.4.1.34.0.6 sysBrdTempMax00
1.3.6.1.4.1.34.0.7 sysBrdTemp91100
1.3.6.1.4.1.34.0.8 sysBrdTempBad00
1.3.6.1.4.1.34.0.9 sysBrdTempChange00
1.3.6.1.4.1.34.0.10 cbTempNorm00
1.3.6.1.4.1.34.0.11 cbTempHigh00
1.3.6.1.4.1.34.0.12 cbTempWarn00
1.3.6.1.4.1.34.0.13 cbTempMax00
1.3.6.1.4.1.34.0.14 cbTemp91100
1.3.6.1.4.1.34.0.15 cbTempBad00
1.3.6.1.4.1.34.0.16 cbTempChange00
1.3.6.1.4.1.34.0.17 centerplaneTempNorm00
1.3.6.1.4.1.34.0.18 centerplaneTempHigh00
1.3.6.1.4.1.34.0.19 centerplaneTempWarn00
1.3.6.1.4.1.34.0.20 centerplaneTempMax00
1.3.6.1.4.1.34.0.21 centerplaneTemp91100
1.3.6.1.4.1.34.0.22 centerplaneTempBad00
1.3.6.1.4.1.34.0.23 centerplaneTempChange00
1.3.6.1.4.1.34.0.24 cbeConnected00
1.3.6.1.4.1.34.0.25 cbeDisconnected00
1.3.6.1.4.1.34.0.26 suppBrdTempNorm00
1.3.6.1.4.1.34.0.27 suppBrdTempHigh00
1.3.6.1.4.1.34.0.28 suppBrdTempWarn00
1.3.6.1.4.1.34.0.29 suppBrdTempMax00
1.3.6.1.4.1.34.0.30 suppBrdTemp91100
1.3.6.1.4.1.34.0.31 suppBrdTempBad00
1.3.6.1.4.1.34.0.32 suppBrdTempChange00
1.3.6.1.4.1.34.0.33 sysBrdVoltNorm00
1.3.6.1.4.1.34.0.34 sysBrdVoltMax00
1.3.6.1.4.1.34.0.35 sysBrdVoltMin00
1.3.6.1.4.1.34.0.36 sysBrdVoltBad00
1.3.6.1.4.1.34.0.37 sysBrdVoltChange00
1.3.6.1.4.1.34.0.38 cbVoltNorm00
1.3.6.1.4.1.34.0.39 cbVoltMax00
1.3.6.1.4.1.34.0.40 cbVoltMin00
1.3.6.1.4.1.34.0.42 cbVoltChange00
1.3.6.1.4.1.34.0.43 centerplaneVoltNorm00
1.3.6.1.4.1.34.0.44 centerplaneVoltMax00
1.3.6.1.4.1.34.0.45 centerplaneVoltMin00
1.3.6.1.4.1.34.0.46 centerplaneVoltBad00
1.3.6.1.4.1.34.0.47 centerplaneVoltChange00
1.3.6.1.4.1.34.0.48 suppBrdVoltNorm00
1.3.6.1.4.1.34.0.49 suppBrdVoltMax00
1.3.6.1.4.1.34.0.50 suppBrdVoltMin00