Server slot powered ON.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.343.2.10.3.5.1000.80.4
Server slot powered ON.
Identification
{1 3 6 1 4 1 343 2 10 3 5 1000 80 4}
The displayed source records contain one distinct definition. Compare its source records.
slotPowerIsOnEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity,
eventSlotDescription,
eventSlotCIMDeviceId
}
STATUS current
DESCRIPTION "Server slot powered ON."
--Novell NMS trap annotation
--TYPE "Server Slot Powered ON"
--SEVERITY INFORMATIONAL
--SUMMARY "Slot %d is now powered ON."
--ARGUMENTS {4}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { slotEvents 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Server slot powered ON.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: slotPowerIsOnEvent
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"slotPowerIsOnEvent",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"eventDescription",
",",
"eventSeverity",
",",
"eventSlotDescription",
",",
"eventSlotCIMDeviceId",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Server slot powered ON.\"",
"::=",
"{",
"slotEvents",
"4",
"}"
],
"syntax_tree": [
[
"Objects",
[
"eventDescription",
"eventSeverity",
"eventSlotDescription",
"eventSlotCIMDeviceId"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Server slot powered ON."
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: INTEL-SERVER-BASEBOARD7
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Counter32', 'Integer32']}Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
· Download INTEL-SERVER-BASEBOARD7Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.343.2.10.3.5.1000.80.1 | slotOKEvent | 0 | 0 | |
| 1.3.6.1.4.1.343.2.10.3.5.1000.80.2 | slotFaultAssertedEvent | 0 | 0 | |
| 1.3.6.1.4.1.343.2.10.3.5.1000.80.3 | slotPowerIsOffEvent | 0 | 0 |