Status in source: mandatory.
Names: eapsLinkScanInterval
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"eapsLinkScanInterval",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"10",
".",
".",
"1000",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Scan interval of port link status for EAPS. The range is from 10ms to 1000ms. Unit is 1ms. For IESwitch, default value is 10ms. For others, default value is 1000ms.\"",
"::=",
"{",
"switchHALGlobal",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
10,
1000
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Scan interval of port link status for EAPS. The range is from 10ms to 1000ms. Unit is 1ms. For IESwitch, default value is 10ms. For others, default value is 1000ms."
],
null,
null,
null,
null
]
}