A value for optical interface trasporting power alarm, 1-over than upper limit, 2-lower than lower limit.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.34751.9.183.3
A value for optical interface trasporting power alarm, 1-over than upper limit, 2-lower than lower limit.
Identification
{1 3 6 1 4 1 34751 9 183 3}
| Value | Name |
|---|---|
| 1 | over |
| 2 | below |
| 3 | normal |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
opIfTransPowerAlarm OBJECT-TYPE
SYNTAX INTEGER{
over(1),
below(2),
normal(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A value for optical interface trasporting power alarm, 1-over than upper limit, 2-lower than lower limit."
::= { opticalPortPower 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A value for optical interface trasporting power alarm, 1-over than upper limit, 2-lower than lower limit.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: opIfTransPowerAlarm
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"opIfTransPowerAlarm",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"over",
"(",
"1",
")",
",",
"below",
"(",
"2",
")",
",",
"normal",
"(",
"3",
")",
"}",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"A value for optical interface trasporting power alarm, 1-over than upper limit, 2-lower than lower limit.\"",
"::=",
"{",
"opticalPortPower",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"over",
1
],
[
"below",
2
],
[
"normal",
3
]
]
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"A value for optical interface trasporting power alarm, 1-over than upper limit, 2-lower than lower limit."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: QTECH-NMS-OPTICAL-PORT-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'SNMPv2-SMI': ['NOTIFICATION-TYPE'], 'RFC1155-SMI': ['Counter', 'IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'ifIndex', 'PhysAddress'], 'QTECH-NMS-SMI': ['nmsMgmt', 'nmsEPONGroup']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.34751.9.183.1 | opticalPortPowerTable | 1 | 16 | |
| 1.3.6.1.4.1.34751.9.183.2 | opIfTransMode | 0 | 0 | |
| 1.3.6.1.4.1.34751.9.183.4 | opIfBERStatus | 0 | 0 | |
| 1.3.6.1.4.1.34751.9.183.5 | nmsOpIfPowerThresNotifications | 1 | 1 | |
| 1.3.6.1.4.1.34751.9.183.6 | opIfUploadBERNotifications | 1 | 1 |