OID reference

diagTestId

1.3.6.1.4.1.351.110.6.3.3

Description

This is used to indicate the test number of the diagnostics test that failed.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.351.110.6.3 (onlineDiagnostics)
Node code
3
Node name
diagTestId
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.351.110.6.3.3
URN notation
urn:oid:1.3.6.1.4.1.351.110.6.3.3
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 351 110 6 3 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) stratacom(351) basis(110) axisDiagnostics(6) onlineDiagnostics(3) diagTestId(3)}
OID-IRI notation
  • /1/3/6/1/4/1/351/110/6/3/3
  • /ISO/Identified-Organization/6/1/4/1/351/110/6/3/3
  • /ISO/3/6/1/4/1/351/110/6/3/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/identified-organization/dod/internet/private/enterprises/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/identified-organization/dod/internet/private/vendor-objects/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/org/dod/internet/private/enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/org/dod/internet/private/enterprises/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/org/dod/internet/private/ldap-enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/org/dod/internet/private/vendor-objects/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-identified-organization/dod/internet/private/enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-identified-organization/dod/internet/private/enterprises/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-organization/dod/internet/private/enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-organization/dod/internet/private/enterprises/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId
  • /iso/iso-organization/dod/internet/private/vendor-objects/stratacom/basis/axisDiagnostics/onlineDiagnostics/diagTestId

SNMP properties

Value type
Integer32, INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current, mandatory

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — Cisco, MIBdepot

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
0–2147483647

Variant 2 — Cisco SMIv1

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Allowed ranges
0–2147483647

Variant 3 — Circitor

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.351.110.6.3.3.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 2

This is used to indicate the test number of the
diagnostics test that failed. The value depends upon
the implementation in the each of the MGX82xx product.
Sources for this description

Historical records

Additional source information

Information from Circitor
diagTestId     OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This is used to indicate the test number of the
                 diagnostics test that failed.
                "
        ::= { onlineDiagnostics 3 }
Information from Cisco SMIv1
diagTestId OBJECT-TYPE
    SYNTAX INTEGER(0..2147483647)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This is used to indicate the test number of the
        diagnostics test that failed. The value depends upon
        the implementation in the each of the MGX82xx product."
    ::= { onlineDiagnostics 3 }
Information from OID Repository
Vendor: Stratacom
Module: CISCO-WAN-AXIPOP-MIB

[Automatically extracted from oidview.com]
Information from MIBdepot
diagTestId     OBJECT-TYPE
    SYNTAX     Integer32(0..2147483647)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "This is used to indicate the test number of the
        diagnostics test that failed. The value depends upon
        the implementation in the each of the MGX82xx product."
    ::= { onlineDiagnostics 3 }
Information from Cisco
diagTestId     OBJECT-TYPE
    SYNTAX     Integer32(0..2147483647)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "This is used to indicate the test number of the
        diagnostics test that failed. The value depends upon
        the implementation in the each of the MGX82xx product."
    ::= { onlineDiagnostics 3 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.351)

Clyde Iwamoto

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.351.110.6.3.3.0 diagTestId00

Siblings (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.351.110.6.3.1 diagType11 This is used to identify the type of diagnostics.
When a trap is sent to report diagnostics results
this is used as a varbind to …
1.3.6.1.4.1.351.110.6.3.2 diagResult11 This is used to indicate the result of the diagnostics
tests in traps.