cmmTransQSFPextendedidentifier — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Extended identifier of QSFP transceiver for additional information.
{1 3 6 1 4 1 36673 100 1 2 2 1 6}
Extended identifier of QSFP transceiver for additional information.
Status in source: current.
Names: cmmTransQSFPextendedidentifier
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cmmTransQSFPextendedidentifier",
"OBJECT-TYPE",
"SYNTAX",
"BITS",
"{",
"powerclass1-1dot5wmax",
"(",
"0",
")",
",",
"powerclass2-2wmax",
"(",
"1",
")",
",",
"powerclass3-2dot5wmax",
"(",
"2",
")",
",",
"powerclass4-3dot5wmax",
"(",
"3",
")",
",",
"cleicode-present",
"(",
"4",
")",
",",
"cdrpresent-in-tx",
"(",
"5",
")",
",",
"cdrpresent-in-rx",
"(",
"6",
")",
",",
"powerclass5-4wmax",
"(",
"7",
")",
",",
"powerclass6-4dot5wmax",
"(",
"8",
")",
",",
"powerclass7-5wmax",
"(",
"9",
")",
",",
"unavailable",
"(",
"30",
")",
",",
"not-applicable",
"(",
"31",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Extended identifier of QSFP transceiver for additional information.\"",
"::=",
"{",
"cmmTransEEPROMEntry",
"6",
"}"
],
"syntax_tree": [
[
"BITS",
[
[
"powerclass1-1dot5wmax",
0
],
[
"powerclass2-2wmax",
1
],
[
"powerclass3-2dot5wmax",
2
],
[
"powerclass4-3dot5wmax",
3
],
[
"cleicode-present",
4
],
[
"cdrpresent-in-tx",
5
],
[
"cdrpresent-in-rx",
6
],
[
"powerclass5-4wmax",
7
],
[
"powerclass6-4dot5wmax",
8
],
[
"powerclass7-5wmax",
9
],
[
"unavailable",
30
],
[
"not-applicable",
31
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Extended identifier of QSFP transceiver for additional information."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: IPI-CMM-CHASSIS-MIB
cmmTransQSFPextendedidentifier OBJECT-TYPE
SYNTAX BITS {
powerclass1-1dot5wmax(0),
powerclass2-2wmax(1),
powerclass3-2dot5wmax(2),
powerclass4-3dot5wmax(3),
cleicode-present(4),
cdrpresent-in-tx(5),
cdrpresent-in-rx(6),
powerclass5-4wmax(7),
powerclass6-4dot5wmax(8),
powerclass7-5wmax(9),
unavailable(30),
not-applicable(31)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Extended identifier of QSFP transceiver for additional information."
::= { cmmTransEEPROMEntry 6 }{'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE', 'enterprises', 'OBJECT-IDENTITY'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi']}Related source files and packages:
Same file in Observium Community.
Downloaded: 2026-10-24T02:14:15.518300+00:00.
Vendor MIB copy from the Observium Community archive.
Module: IPI-CMM-CHASSIS-MIB
cmmTransQSFPextendedidentifier OBJECT-TYPE
SYNTAX BITS {
powerclass1-1dot5wmax(0),
powerclass2-2wmax(1),
powerclass3-2dot5wmax(2),
powerclass4-3dot5wmax(3),
cleicode-present(4),
cdrpresent-in-tx(5),
cdrpresent-in-rx(6),
powerclass5-4wmax(7),
powerclass6-4dot5wmax(8),
powerclass7-5wmax(9),
unavailable(30),
not-applicable(31)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Extended identifier of QSFP transceiver for additional information."
::= { cmmTransEEPROMEntry 6 }{'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE', 'enterprises', 'OBJECT-IDENTITY'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi']}Related source files and packages:
Downloaded: 2026-10-24T02:14:23.853191+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.36673.100.1.2.2.1.52 | cmmTransXFPOptionsImp | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.2.2.1.53 | cmmTransXFPVoltageAuxMonitor | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.2.2.1.54 | cmmTransXFPEncoding | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.2.2.1.55 | cmmTransWavelength | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.2.2.1.56 | cmmTransChannelNumber | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.2.2.1.57 | cmmTransGridSpacing | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.2.2.1.58 | cmmTransLaserFirstFrequency | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.2.2.1.59 | cmmTransLaserLastFrequency | 0 | 0 |